inS_cnge2fe16MS_reV–
01/11/12 Page 10
INSTALLATION AND OPERATION MANUAL
CNGE2FE16MS
TECh SUPPORT: 1.888.678.9427
LED Indicators
LED indicators located on the front panel display the power status and network status of the
CNGE2FE16MS. Please Table 1 for further details.
LED
Color
Description
PWR
Green
On
System power on
Off
No power inputs
R.M.
Green
On
The switch is the master device of the X-ring group
Off
Non-master device
PWR1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
PWR2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
P-Fail
(depends on the Fault
Relay Alarm configuration)
Red
On
Power or Ethernet port linking failure occurs
Off
No failure occurs
P1 ~ P16
Green
On
Connected to network
Blinking Data is transmitting or receiving
Off
Not connected to network
Amber
On
Full duplex
Blinking Collision of packets occurs
Off
Half duplex or not connected to network
P17, P18
(10/100/1000T)
Green
(Upper LED)
On
Connected to network
Blinking Data is transmitting or receiving
Off
Not connected to network
Green
(Lower LED)
On
Operating at speed of 1000M
Off
Disconnected or operating at speed of 10/100M
P17, P18
(100/1000 SFP)
Green
On
Connected to network
Blinking Data is transmitting or receiving
Off
Not connected to network
Table 1 – Definition of LED indicators