background image

INSTALLATION AND OPERATION MANUAL 

CNGE2FE16MS

Managed ethernet Switch with (16) 10/100tX +  

(2) configurable 10/100/1000tX / 100/1000fX PortS

v2.01 Jan 2012

The ComNet™ CNGE2FE16MS Managed Ethernet Switch provides robust transmission 
of (16) 10/100 BASE-TX and (2) 10/100/1000TX or 100/1000FX combo ports, of gigabit 
Ethernet data. Unlike most Ethernet switches, these environmentally hardened units 
are  designed  for  direct  deployment  in  difficult  out-of-plant  or  roadside  operating 
environments,  and  are  available  for  use  with  either  conventional  CAT-5e  copper  or 
optical transmission media. Diverse media selection allows for easy implementation 
of point-to-point, linear add-drop, drop-and-repeat, star, or true self-healing ring and 
mesh network system architectures. The 16 electrical ports support the 10/100 Mbps 
Ethernet IEEE 802.3 protocol, and auto-negotiating and auto-MDI/ MDIX features are 
provided for simplicity and ease of installation. 2 ports are 10/100/1000 configurable 
for copper or fiber media for use with multimode or single mode optical fiber, selected 
by  optional  SFP  modules.  These  network  managed  layer  2  switches  are  optically 
(100/1000  BASE-FX)  and  electrically  compatible  with  any  IEEE  802.3  compliant 
Ethernet devices. Plug-and-play design ensures ease of installation, and no electrical 
or  optical  adjustments  are  ever  required.  The  CNGE2FE16MS  incorporates  LED 
indicators for monitoring the operating status of the managed switch and network. 
These units are DIN-rail or wall mountable.

Summary of Contents for CNGE2FE16MS

Page 1: ...oint linear add drop drop and repeat star or true self healing ring and mesh network system architectures The 16 electrical ports support the 10 100 Mbps Ethernet IEEE 802 3 protocol and auto negotiat...

Page 2: ...are Description 9 Physical Dimensions 9 LED Indicators 10 Installation 11 RJ 45 Cabling 11 SFP Cabling 15 Grounding the CNGE2FE16MS 17 Wiring the Power Inputs 18 Wiring the P Fail Alarm Contacts 19 DI...

Page 3: ...owever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...

Page 4: ...ion that complies with IP30 standards Dual Power Inputs The redundant power input design for the CNGE2FE16MS provides a backup power solution With both the power inputs supplied if a failure occurs th...

Page 5: ...9427 Features 7 2Gbps back plane switching fabric 2 x 1000Base T 1000Base FX Combo ports Wide range redundant power Power polarity reversal protection X Ring II path redundant supported TFTP firmware...

Page 6: ...ctivity Management Configuration Web browser serial console SNMP v1 v2c v3 Telnet TFTP N Key optional IPv6 SNTP SNMP MIB RFC 1215 Trap RFC1213 MIBII RFC 1157 SNMP MIB RFC 1493 Bridge MIB RFC 2674 VLAN...

Page 7: ...Operating Temperature 40 75 C 40 167 F Operating Humidity 5 95 non condensing Storage Temperature 40 85 C 40 185 F Storage Humidity 5 95 non condensing MTBF 218490 hrs Certifications Safety UL cUL CE...

Page 8: ...sub 9 female console cable 1 x User Manual CD ROM 1 x Wall mount kit Compare the contents of the CNGE2FE16MS with the standard checklist above If any item is damaged or missing please contact the loca...

Page 9: ...port 1 888 678 9427 Hardware Description This section is intended to introduce the industrial switch s hardware specification port cabling and wiring information Physical Dimensions Figure 1 illustrat...

Page 10: ...2 is inactive P Fail depends on the Fault Relay Alarm configuration Red On Power or Ethernet port linking failure occurs Off No failure occurs P1 P16 Green On Connected to network Blinking Data is tr...

Page 11: ...pper ports will auto sense for 10Base T 100Base TX or 1000Base T connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing straight through or cross...

Page 12: ...matic Figure 3 Cross Over Cable Schematic 10 100 1000Base T Pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi dir...

Page 13: ...LLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 10 100 1000Base T Cable Schema The following two figures illustrate the 10 100 1000Base T cable schema Figure 4 Straight Through Ca...

Page 14: ...g into the SFP socket with proper multi mode or single mode fiber cable according to that transceiver Note The particular SFP Copper Combo port is deemed to be a single port that either the SFP or Cop...

Page 15: ...iver and the LC cable please follow the steps shown in Figures 6 8 First insert the transceiver into the SFP slot Notice that the triangle mark indicates the bottom of the slot Figure 6 Insert transce...

Page 16: ...he LC connector from the transceiver follow the steps showin in Figures 9 and 10 First press down the latches and pull the LC connector out of the transceiver Figure 9 Press down the latches to remove...

Page 17: ...ctions below to attach the CNGE2FE16MS to ground Attention When installing the CNGE2FE16MS the ground connection must always be made first and disconnected last On the top of the CNGE2FE16MS locate an...

Page 18: ...ions for the terminal block connection See the symbols printed on the panel indicating the polarities and DC input power range in voltage Figure 12 Plugs for Power 1 Power 2 Insert the exposed wires i...

Page 19: ...energized upon powering up of the switch and remain energized until a critical error occurs including power failure Ethernet port disconnection and MAC violation Take the wiring illustration below as...

Page 20: ...he DIN rail clip is screwed on the CNGE2FE16MS when out of factory If not please refer to the following steps to secure the DIN rail clip on the switch Use the included screws to secure the DIN rail c...

Page 21: ...IN rail First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail Figure 17 Positioning DIN rail clip on the DIN rai...

Page 22: ...switch on the wall please follow the steps below Remove the DIN rail clip Prepare the two wall mount plates and six screws included Align the screw holes between the wall mount plates and the unit as...

Page 23: ...ow to wire the power And then the power LED on the CNGE2FE16MS will light up Please refer to the LED Indicators section for indication of LED lights Prepare the appropriate cables for the Ethernet con...

Page 24: ...he supplied cable which one end is D sub 9 and the other end is RJ 45 to connect the CNGE2FE16MS and your host PC or terminal The connected PC or terminal must support the terminal emulation program F...

Page 25: ...tween Switch and PC is ready turn on the PC and run a terminal emulation program like Hyper Terminal and configure its communication parameters to match the following default characteristics of the co...

Page 26: ...nd Password press Enter to switch between and then press Enter to reach the Main Menu of console management Figure 23 Console login interface The system supports the console management CLI command Aft...

Page 27: ...thernet switch Configuring PuTTY Launch PuTTy and you will see a dialog box that allows you to control everything PuTTY can do You do not usually need to change most of the configuration options To st...

Page 28: ...SH Connections Select the Connection4 SSH4 Tunnel node of the tree menu to configure options for controlling SSH port forwarding Tick the check box labeled Local ports accept connection from other hos...

Page 29: ...ll see an entry added to the list box Figure 28 Entry of Port Forwarding Added You can also save your preferred PuTTY options for a quick connection the next time it is needed Just go back to the Sess...

Page 30: ...erver select the session name and select the Open button And then you will see a window shows up with prompt message login as Type guest for both user name and password Figure 30 Logging in interface...

Page 31: ...GE2FE16MS_REV 01 11 12 PAGE 31 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 When finished a telnet session is successfully made using the SSH protocol Figure 32 Console vi...

Page 32: ...aight through or crossover Ethernet cable Before using web management install the CNGE2FE16MS on the network and make sure that any one of the PCs on the network can connect with the CNGE2FE16MS throu...

Page 33: ...rd in the User Authentication section Figure 34 Login dialog box SSL The CNGE2FE16MS also provides an option for you to connect with your browser via HTTP over SSL called HTTPS The SSL Secure Socket L...

Page 34: ...2FE16MS Tech Support 1 888 678 9427 On the left side of the main page you can find the tree menu structure of the Ethernet switch Select the symbol to expand a category and select any one of the hyper...

Page 35: ...h is 64 bytes System Description A read only field displaying the description of the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the...

Page 36: ...e DHCP server IP Address Assign the IP address for the CNGE2FE16MS With the DHCP Client function enabled the switch is configured as a DHCP client and users don t need to assign the IP address that is...

Page 37: ...INS_CNGE2FE16MS_REV 01 11 12 PAGE 37 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 38 IP configuration IPv4...

Page 38: ...segment whith one or more routers connected the switch will be assigned an address known as Global Unicast Address by the router s Being assigned the Global Unicast Address the CNGE2FE16MS can then ha...

Page 39: ...ides the DHCP server function With the DHCP server function enabled the switch can be configured as a DHCP server System Configuration DHCP Server This pull down menu allows you to configure the switc...

Page 40: ...6MS Tech Support 1 888 678 9427 When the DHCP Server function is enabled the system will collect the DHCP client information including the assigned IP address the MAC address of the client device the...

Page 41: ...2 the switch will assign the IP address to the connected client according to the Port IP binding table The user is allowed to fill each port with one particular IP address When the device connects to...

Page 42: ...er to update the switch firmware Before updating make sure the TFTP server is ready and the firmware image is located on the TFTP server Update Firmware TFTP Server IP Address Type in the IP address o...

Page 43: ...TFTP server to recover the settings Before doing that you must locate the image file on the TFTP server first for the switch to download back the flash image TFTP Server IP Address Type in the IP add...

Page 44: ...lash ROM to the TFTP server for the purpose of recovering the configuration at another time It helps avoid wasted time spent configuring the settings by backing up the entire configuration TFTP Server...

Page 45: ...Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only be sent to the remote system log server...

Page 46: ...s occur SMTP Server IP Address Assign the mail server IP address when Email Alert is enabled this field will then be available Sender Type in an alias of the switch in complete email address format e...

Page 47: ...lure and MAC Violation Device Cold Start Check the Syslog SMTP checkboxes respectively to have the system issue the event log email alert to the system log SMTP server when the device executes the col...

Page 48: ...INS_CNGE2FE16MS_REV 01 11 12 PAGE 48 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 48 Event Configuration interface...

Page 49: ...installation Power Failure With the checkbox selected the relay device inside the CNGE2FE16MS changes its state and the FAULT LED indicator is on if a power failure occurs Port Link Down Broken With...

Page 50: ...provides comprehensive mechanisms to access national time and frequency dissemination services organize the time synchronization subnet and the local clock in each participating subnet peer Daylight S...

Page 51: ...aylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Win...

Page 52: ...ng a colon mark hour minute specification For example key in 20070701 02 00 and 20071104 02 00 in the two fields respectively to represent that DST begins at 2 00 a m on March 11 2007 and ends at 2 00...

Page 53: ...le HTTP Server With this checkbox selected Ethernet devices whose IP addresses match any one of the ten IP addresses in the Security IP table will be given permission to access this switch via the HTT...

Page 54: ...t Type in the User Name field with a new name as you wish New Password The password to the admin user account is admin by default Specify a new password as you wish Confirm password Type in the new pa...

Page 55: ...the system configuration from N Key when booting up Backup Make sure N Key is connected with the RS 232 console port and then select this button to back up the current configuration from the switch Re...

Page 56: ...or receive any packet Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 bytes oversize CRC Ali...

Page 57: ...read only field displaying in grey Duplex It is available for selecting when the Negotiation field is set on Force When the Negotiation field is set on Auto this field becomes a read only field displa...

Page 58: ...INS_CNGE2FE16MS_REV 01 11 12 PAGE 58 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 55 Port Control interface...

Page 59: ...group including member ports split between two switches has to enable the LACP function of the two switches When disabled the trunk group is a static trunk group The advantage of having the LACP disa...

Page 60: ...FE16MS_REV 01 11 12 PAGE 60 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 56 Port Trunk Aggregator Setting interface four ports are added to the left field with LACP...

Page 61: ...setting with LACP disabled you can check the static trunk group information on the Aggregator Information tab Figure 57 Assigning 2 ports to a trunk group with LACP disabled Figure 58 Static Trunking...

Page 62: ...the Aggregator Information tab Configuration for Switch 1 Set System Priority of the trunk group The field displays 1 by default Select a trunk Group ID by selecting the pull down menu Enable LACP Inc...

Page 63: ...AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 60 Aggregation Information of Switch 1 Select the Aggregator Information tab to check the trunked group information as the illustrat...

Page 64: ...tion Interface Set System Priority of the trunk group The field displays 1 by default Select a trunk Group ID by selecting the pull down menu Enable LACP Include the member ports by highlighting the p...

Page 65: ...AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 62 Aggregation Information of Switch 2 Select the Aggregator Information tab to check the trunked group information as the illustrat...

Page 66: ...he select mark of the corresponding port and select the Apply button the port state activity will change to Passive Active The port automatically sends LACP protocol packets Passive The port does not...

Page 67: ...roring interface Destination Port Select one port to be the destination mirroring port for monitoring both RX and TX traffic coming from the source port Or select two ports for monitoring RX traffic a...

Page 68: ...each port Ingress Limit Frame Type Select the limit type for ingress frames Four options are available as follows All Broadcast Multicast Flooded Unicast Broadcast Multicast Broadcast only The egress...

Page 69: ...down the device or the other one labeled as e mail to send e mail for notifications when the port temperature reaches the threshold Voltage The fields showing values measured in voltages Select the ra...

Page 70: ...of the same broadcast domain The valid VLAN ID is in the range of number between 1 and 4094 The amount of VLAN groups is up to 256 including the default VLAN that cannot be deleted GVRP GARP VLAN Reg...

Page 71: ...Hybrid Links the communication across switches also can make the packet sent through tagged and untagged ports This switch supports IEEE 802 1Q in Q or IEEE 802 1ad standard developed to break throug...

Page 72: ...ailable while the VLAN Operation Mode is set on 802 1Q Management VLAN ID Only the VLAN members whose Untagged VID PVID equals to the value specified in this field have permission to access the switch...

Page 73: ...the tagged VID field The trunk port will forward the frames of VLAN 1 The trunk port has to be connected to a trunk hybrid port of the other switch Both the tagged VID of the two ports have to be the...

Page 74: ...LAN Groups Select the Group Configuration tab Select a VLAN group in the list box and select the Edit button Figure 70 Group Configuration interface After selecting the Edit button you can change Grou...

Page 75: ...the highest priority and will be selected as the admin device If the value is changed users must reboot the switch Note the value specified in the Priority field must be a multiple of 4096 according t...

Page 76: ...ort This field indicates which port is connecting to the root bridge When the switch is set as the root bridge the word Root shows here Root Path Cost This field displays the path cost between the swi...

Page 77: ...e within RSTP are dependent upon whether the port concerned can only be connected to exactly another bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges...

Page 78: ...INS_CNGE2FE16MS_REV 01 11 12 PAGE 78 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 73 RSTP Port Configuration interface...

Page 79: ...SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve netw...

Page 80: ...is given the read only permission for the MIB objects RW Read write With this radio button selected the community string is given the read write permission for the MIB objects Select Add to finish add...

Page 81: ...ued To define a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version IP Address Enter the IP address of the trap manager Communit...

Page 82: ...d Assign the authentication password to the user ID Privacy Password Assign the private password to the user ID Select the Add button to create a new user profile To remove a user profile select an en...

Page 83: ...CNGE2FE16MS_REV 01 11 12 PAGE 83 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 76 SNMPv3 configuration interface Access Table Figure 77 Configure the SNMPv3 access t...

Page 84: ...to determine the context matching rule You can configure it as a complete matching or prefix matching condition Read View Name Assign permission of reading to a user ID type that exists in the User Ta...

Page 85: ...r queues to which allocate traffic in the rate of 8 4 2 1 As for the strict priority scheme traffic will be identified according to the priority determined QoS Policy Select the QoS policy rule Use an...

Page 86: ...ation take effect CoS Configuration Configure this item to allocate the identified packet to different queues according to the packet s 3 bit 802 1p priority classification field that is embedded in t...

Page 87: ...d Service Code Point value inside the 1 byte ToS Type of Service field The 6 bit DSCP value defines up to 64 priority values Therefore you can assign one of the four queues to each priority respective...

Page 88: ...ports If the failure of network connection occurs the backup ports of master switches ring master devices will automatically become working forwarding ports to recover from the failure X Ring2 Operati...

Page 89: ...INS_CNGE2FE16MS_REV 01 11 12 PAGE 89 INSTALLATION AND OPERATION MANUAL CNGE2FE16MS Tech Support 1 888 678 9427 Figure 80 X Ring2 Interface...

Page 90: ...X Ring It protects a network with the most secure topologies ever X Ring II works as a chain of rings to reduce the risk of master switch failure or link down X Ring II is backwards compatible with ex...

Page 91: ...MS Tech Support 1 888 678 9427 Coupled X Ring II Recover Time 10ms Maximum switches 256 Backup masters 256 Terminal Server IP Camera Ring Ring Data Collection Server Traffic Signal Control Equipment F...

Page 92: ...ng II Recover Time 10ms Maximum switches 256 Backup masters 256 Terminal Server IP Camera Ring Data Collection Server Traffic Signal Control Equipment Field Management Human Management Interface Termi...

Page 93: ...TP ring Recover Time 10ms X Ring II Recover Time 10ms Maximum switches 256 Maximum switches 50 Backup masters 256 Backup masters 50 Data Collection Server Human Management Interface Terminal Server IP...

Page 94: ...8 9427 Dual Homing Three X Ring II Recover Time 10ms Maximum switches 50 Backup masters 50 Data Collection Server Human Management Interface IP Camera Ring Terminal Server Traffic Signal Control Equip...

Page 95: ...ng Port Use the pull down menu to select a port as the first ring port 2nd Ring Port Use the pull down menu to select a port as the second ring port When finished select the Apply button to have the c...

Page 96: ...over the data link layer only allowing two systems running different network layer protocols to learn about each other The switch also supports LLDP MED Media Endpoint Devices that is the enhanced st...

Page 97: ...his function IEEE 802 1x Protocol Use the pull down menu to Enable or Disable the 802 1x protocol on the switch Radius Server IP Assign the RADIUS Server IP address Server Port Set the UDP destination...

Page 98: ...ed to be held in the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or Unauthorized state in accordan...

Page 99: ...ant Timeout Set the period of time the switch waits for a supplicant response to an EAP request Server Timeout Set the period of time the switch waits for a server response to an authentication reques...

Page 100: ...nnected to the switch This saves the switch from having to re learn a device s MAC address when the disconnected or powered off device is active on the network again Via this interface you can add mod...

Page 101: ...7 MAC Filtering The switch will block traffic from devices with the MAC address listed in this table Figure 92 MAC Filtering interface MAC Address Enter up to 256 MAC addresses Select the Add button I...

Page 102: ...ll MAC Addresses This tab displays dynamic and static MAC addresses on each port Port No Use the pull down menu to select a particular port to show its MAC address information Select the Clear MAC Tab...

Page 103: ...s Multicast Listener Discovery MLD is used in a similar way by IPv6 systems With the switch supporting IP multicast you can enable IGMP MLD protocol via this interface Destination IP multicast address...

Page 104: ...ddress like 01 00 5E xx xx xx for the multicast group from which end stations can receive multicast traffic via the connected ports that have been included in the specific multicast groups With multic...

Page 105: ...user name password Figure 96 Factory Default interface Save Configuration Save all changes you have made in the system To ensure the configurations you have made will be implemented the next time you...

Page 106: ...e easily monitored through LED indicators on the front panel These indicators describe common problems you may encounter and where you can find possible solutions to assist in identifying and solving...

Page 107: ...EXEC mode switch Enter disable to exit The privileged commands are the advanced mode Use this mode to Display advance function states Save configurations Global Configuration Enter the configure comma...

Page 108: ...address Ip address Subnet mask Gateway G Configure the IP address of switch switch config ip address 192 168 1 1 255 255 255 0 192 168 1 254 ip dhcp G Enable DHCP client function of switch switch con...

Page 109: ...me 1 dhcpserver ipbinding IP address I Set static IP for DHCP clients by port switch config interface fastEthernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P S...

Page 110: ...if speed 100 flowcontrol enable disable I Configure flow control switch config if flowcontrol enable security enable I Enable security of interface switch config interface fastEthernet 2 switch config...

Page 111: ...ernet 2 switch config if bandwidth out 160 show bandwidth I Show interfaces bandwidth control switch config interface fastEthernet 2 switch config if show bandwidth alias name Set port alias name swit...

Page 112: ...ggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 aggregator activityport Group ID Port Numbers G Set activity port switch config aggregator activityport 1 2 ag...

Page 113: ...config if dmi current highalarm shutdown dmi txpwr HighAlarm HighWarning LowWarning LowAlarm E mail ShutDown I Set reactions for port transmitting power monitoring switch config interface fastEtherne...

Page 114: ...r VLAN by port If the port belongs to a trunk group this command can t be applied switch vlan vlan 8021q port 3 qinq untag 4 tag 3 6 8 or switch vlan vlan 8021q port 3 qinq untag 5 tag 6 8 vlan 8021q...

Page 115: ...nfig spanning tree max age 15 spanning tree hello time seconds G Use the spanning tree hello time global configuration command to specify the interval between hello bridge protocol data units BPDUs sw...

Page 116: ...fig interface fastEthernet 2 switch config if stp admin non stp False show spanning tree E Display a summary of the spanning tree states switch show spanning tree no spanning tree G Disable spanning t...

Page 117: ...plays the details of an IGMP snooping entries switch show igmp multi no igmp G Disable IGMP snooping function switch config no igmp no igmp query G Disable IGMP query switch config no igmp query MLD C...

Page 118: ...nfig interface fastEthernet 2 switch config if mac address table static hwaddr 000012345678 mac address table filter hwaddr MAC G Configure the MAC address table filter switch config mac address table...

Page 119: ...c right rw snmp server host IP address community Community string trap version v1 v2c G Configure SNMP server host information and community string switch config snmp server host 192 168 1 50 communit...

Page 120: ...server host switch config no snmp server host 192 168 1 50 no snmpv3 user User Name G Remove the specified user of the SNMPv3 agent switch config no snmpv3 user test01 no snmpv3 access context name Co...

Page 121: ...ommands Level Description Example 8021x enable G Use the 802 1x global configuration command to enable 802 1x protocols switch config 8021x enable 8021x system radiusip IP address G Use the global con...

Page 122: ...switch config 8021x misc reauthperiod 3000 8021x portstate disable reject accept authorize I Use the configuration command to set the state of the selected port switch config interface fastethernet 3...

Page 123: ...password password password confirm password password G Configure authentication password switch config smtp password password 1234 confirm password 1234 smtp rcptemail Index Email address G Configure...

Page 124: ...tch config no event authentication failure both no event mac violation Systemlog SMTP Both G Disable the event type of MAC Violation switch config no event mac violation both no event systemlog I Disa...

Page 125: ...01 01 sntp daylight offset Minute G Set offset of daylight saving time If SNTP is inactive this command can t be applied switch config sntp daylight offset 3 sntp ip IP G Set the SNTP server IP If SNT...

Page 126: ...te an X Ring2 entry switch config ring2 del 1 ring2 show G Show X Ring2 configuration switch config ring2 show no ring2 G Disable X Ring2 switch config no ring2 show ring2 P Show X Ring2 configuration...

Page 127: ...on Example lldp enable G Enable LLDP function switch config lldp enable lldp interval TIME sec G Configure LLDP interval in seconds switch config lldp interval 1800 show lldp P Show LLDP information s...

Page 128: ...ch Support 1 888 678 9427 info comnet net 8 Turnberry Park Road Gildersome Morley Leeds UK LS27 7LE T 44 0 113 307 6400 F 44 0 113 253 7462 info Europe comnet net MECHANICAL INSTALLATION INSTRUCTIONS...

Reviews: