VIII - Troubleshooting guide
b) What to do in case of a power cut
Nature of error
Causes
Solutions
Flashing red LEDs Items 2&3
Fig. VII-1 + touch screen off
Power cut + Batteries out of order
Fuse out of order + batteries out
of order
Disconnect the power
replace the LR6 1.5-V bat
reboot. If the unit does not
start up, a certified technician
must replace the 5 x 20 mm F
500 mA AH fuse according to the
procedure, or call COMAP after-
sales service
Flashing red LEDs Item 3 Fig. VII-1 General error
Press the touch screen to reac-
tivate the screen and follow the
instructions in the Maintenance
menu: "Notifications and mal-
functions"
UVc lamp NOK
Worn lamp > 12,000 H
Lamp blown
Ballast inoperative
Replace the UVc lamp Replace
the UVc lamp Contact COMAP
after-sales service
Spent cartridges
Clogged prefilter
Life > 1 year
Clogging detected by deltaP
Pressure sensor problem
Pressure sensor calibration
Replace the cartridge
Clean the prefilter
Spent batteries
Life > 1 year
Power cut > a few days
Replace the LR6 1.5 V batteries
Dangerous pressure notification
Pressure above 4 bars
Water hammer
Install or replace a pressure re-
ducer Install a water hammer
prevention device Contact COM-
AP after-sales service
Network leak notification
Volume of water that has flowed
without interruption > 500 L
Check the water system (flush
or tap left running or obvious or
hidden leak). Manually open the
inlet valve if no leak is found, or
call COMAP after-sales service.
Screen frozen, touch screen
inoperative, bug
Firmware inoperative
Program updated via USB key via
a qualified technician. Contact
COMAP after-sales service
Water leak in the machine
Badly tightened unions, damaged
seals, old seals, crack following an
overpressure, shocks, etc.
Close the device's inlet valve, set
it to bypass (shunt), and contact
COMAP after-sales service.
Disconnect the power supply cable from the unit. The unit will restart in Maintenance
Mode, powered by the battery unit. Next, remove the cover by removing the
four screws.
If the electrical power supply is absent, the anti-scaling treatment and disinfection
treatment (UVc lamp) functions will not be provided. The device's power operated
inlet valve will be closed via an interlock via the battery unit. The power operated
valve can be opened to obtain untreated water (the 90μm/40μm filtration and
anti-drop, micropollutant treatments are still active) by actuating the pushbutton
(Fig. VII-1) using a fine screwdriver. If the power cut continues for a long time, you can
switch the battery unit OFF to preserve battery life. Note: this operation will prevent
the power-operated inlet valve from being operated again (closed or opened) without
mains power being restored.
Disconnect the device's power supply cable before any maintenance operation takes
place. The unit will restart in Maintenance Mode, powered by the battery unit. Next,
remove the cover by removing the four screws.
Clean quartz tube and replace O-rings and quartz tube bearing seals. We
recommend you call on a certified technician or call COMAP after-sales service to
find out the details and procedures of these preventive maintenance actions.
Replacing the pressure sensors: the inlet and outlet pressure sensors are intended
to be recalibrated via the maintenance menu on the touch screen. Contact
COMAP after-sales service to obtain the recalibration procedure or to replace any
defective sensors.
Replacing the power operated valves: these valves are designed to perform many
opening and closing cycles. Contact COMAP after-sales service in case of any
defect.
Replacing the filter bowl O-rings: the filter bowl seals are wear parts that can
deteriorate over time and after repeated handling. Plan for their preventive or
corrective replacement in case of incorrect placement in the filter bowl groove
(pinching).
Prefilter mesh: self-cleaning. Can also be deep-cleaned by removing the bowl
from the prefilter and using a brush. Contact COMAP after-sales service to obtain
a procedure.
Seals: the purpose of the flat O-rings is to seal the device. They should be replaced
preventively within five years because of ageing.
Flow meter: the turbine must be cleaned preventively, or correctively in the event
of a clog. Contact COMAP after-sales service to find out the procedure.
Electronic board: to be replaced only in the event of failure. Remember to
disconnect it in the event of a storm or voltage surge. Contact COMAP after-sales
service in case of any malfunction.
Touch screen: the touch screen must be cleaned once a year using a product
suitable for touch screens. Do not use water, detergents, or any other product
not described as being suitable for cleaning touch screens. Do not carry out this
operation whilst the device is in operation.