13
12
Use the box as a template and
use a level to mark the mounting
points for the unit. Use the unit
mounting points on the box.
Take care to place the box in the correct
orientation.
Measure the hardness of your water (TH) using the test
strips supplied with the Komeo unit. To do this, immerse
a test strip in a glass of tap water. Shake off the excess
water, wait one minute, and then compare the colour
to the scale shown above. This value will affect the anti-
scaling power setting you apply to Komeo (to perform this
measurement, read the instructions on the test strips and
read the value in °f) or in °e).
Drill using a 6-mm diameter drill bit (the correct diameter
for the wall plugs supplied with the equipment).
These wall plugs are for use in a dense material.
You should check whether these wall plugs are appropriate
for your substrate. If not, you must obtain appropriate
wall plugs.
Remove the wall plugs from the screws and place the
spacers between screw and wall plug. Choose appropriate
wall plugs for the material and the weight of the machine
(25 kg with water, with four mounting points).
Insert the wall plugs in the holes, allowing the screw to
protrude 5 mm beyond the spacer.
Place Komeo on its mounting points, check that the spacers
are correctly positioned (between the machine and the
wall), and tighten the four mounting screws.