travel 600
19
6 CHECKING, CLEANING AND CHANGING OF PARTS
For all checking, cleaning and changing of parts of the travel 600 the cable must be disconnected. These
works must not be carried out near the escalator/travelator.
Wear protective gloves at all times to prevent the risk of injuries (e.g. cutting at sharp
edges).
6.1 Brushes
How to change dirty or faulty brushes (41):
Loosen all screws (42) of the side covering (43)
Take off the side covering.
Take out the brushes
Change the brushes
If necessary grease screws
Put back the side covering
6.2 Vacuuming cylinder (sucking role)
How to change a dirty or faulty vacuuming cylinder (44):
Loosen screws (42) of side covering (43)
Take off the side covering
Take out the vacuuming cylinder
Change vacuuming cylinder (Pay attention to side of the vacuuming cylinder it is stemped on the
side of the cylinder. Just insert a left for a left and a right for a right cylinder!)
If necessary grease screws
Put back the side covering
In order to obtain optimal cleaning results the space where the brushes (41) and the vac-
uuming cylinder (44) are situated should be checked for soiling (tilting the machine side-
41
42
43
44
(41) brush
(42) screw
(43) side covering
(44) sucking role
Summary of Contents for Travel 600
Page 26: ...travel 600 26 10 2 Space for your notes...