6.1 DRAIN CONNECTION
It is not necessary to connect the processor to an external drain facility – the processor is
supplied with 3 x 10 litre container which are used to collect the waste Developer, Bleachfix and
Superstabi solutions. The containers are fitted with a high-level alarm device, when full they have
to be emptied.
The above mentioned level sensor is used to control the level inside the waste container.
In case one of the sensors is recognizing high level, the processor will bring the message
"WasteX high level".
This indication informs the operator that the waste container must
be emptied or replaced with a fresh empty tank.
Levelsensor
(Highlevel)
DEV
BF
SS
Levelsensor
(Highlevel)
Levelsensor
(Highlevel)
The waste tanks are filled in two ways:
• manually, by opening the overflow
pipes in the tanks (to drain the tank)
• automatically, through the overflow
pipes in the tanks.
Full waste tanks have to be collected
by an authorised waste treatment
company.
Overflow SS
Overflow BF
Overflow DEV
6.2 WATER DRAIN (OPTIONAL)
As mentioned before, in case the processor is supplied with as a non-washless
version,the corresponding drain-tube has to be connected.