In-Sight 5000 Series Vision Systems
In-Sight 5000 series vision systems feature two built-in, high-speed outputs. Both of the high-speed outputs are NPN
(current sinking) lines.
Specification
Description
Voltage
28VDC maximum through external load.
Current
All In-Sight 5000 series
(except In-Sight 5600 series)
200mA maximum sink current.
OFF state leakage current 200µA maximum.
External load resistance 140 Ohms to 10 kOhms.
Each line rated at a maximum 200mA, protected against over-
current, short circuit and transients from switching inductive loads.
High current inductive loads require external protection diode.
In-Sight 5600 series
100mA maximum sink current.
OFF state leakage current 200µA maximum.
External load resistance 280 Ohms to 10 kOhms.
Each line rated at a maximum 100mA, protected against over-
current, short circuit and transients from switching inductive loads.
High current inductive loads require an external protection diode.
Delay
12
±5µs (maximum due to opto-isolators turning ON).
CAUTION
:
l
Do not connect a high-speed output to HS COMMON or OUT COMMON. Use 24V Common for the return.
l
Since both high-speed outputs share a common return (24V Common), when both HS OUT 0 and HS OUT 1
are used, both must be current sinking.
l
Do not use the high-speed outputs if you need to isolate your connections. Use the general-purpose
outputs, which are optically isolated.
1
Delay when opto-isolators turn OFF depends on the load to which the output is connected. With a 240 Ohm load, the maximum delay will be
±5µs.
2
If HS OUT 1 is configured as a Strobe output type within In-Sight Explorer, the maximum strobe latency is ±5µs. For more information, refer to
the