Connector/Indicator
Description
LAN Port
Connects the I/O module to an Ethernet network.
LAN Port LEDs
The green LED blinks when a network connection to the local area network is
detected. The orange LED blinks when network activity is detected.
CC-Link Status LEDs
CIO-MICRO-CC only: Green and red LEDs that illuminate to indicate RUN, ERR,
SD, and RD for a CC-Link operation status.
Frame Ground Terminal
Connects the I/O module to a frame ground.
RS-232 Port
Connects the I/O module to an external serial device using an RS-232 (DB9) serial
cable. Provides RS-232 communications to the vision system.
High-Speed Output Status LEDs
(HS OUT 0 and HS OUT 1)
Green LEDs that illuminate to indicate the high-speed output signal for the In-Sight
vision system has switched ON. The LEDs will illuminate even if the I/O module’s
high-speed terminals are not connected to anything. In addition, the I/O module
displays the last known state of the high-speed output line, therefore the LEDs may
be illuminated even if the vision system is disconnected from the I/O module.
I/O and Trigger Status LEDs
Green LEDs that illuminate to indicate that an input/output signal has switched ON.
Terminal Blocks
Connects the I/O module to 24VDC power, trigger, external I/O, high-speed
outputs, CC-Link (CIO-MICRO-CC only) and common connections.
CAUTION
:
When connecting the In-Sight 7000 series vision system to the
CIO-MICRO or CIO-MICRO-CC I/O module, the I/O module's ,
TRIGGER-, HS OUT 0, HS OUT 1 and HS COMMON terminals are not
supported. Do not connect wire leads from remote devices to these terminals.
Note
:
l
The I/O module's high-speed output terminals (labeled HS OUT 0 and
HS OUT 1) correspond to the In-Sight Micro and 5000 series vision
system’s built-in high-speed outputs. These signals are considered
high-speed because they pass directly through the I/O module without
processing, which provides minimal delay.
l
The I/O module does not provide access to the In-Sight 7000 series
vision system's high-speed outputs. The In-Sight 7000 series vision
system's high-speed outputs are only accessible from the vision
system's Breakout cable.
12
Installation