In-Sight Vision System Connections
Note the following regarding connections to the I/O module:
l
By default, the I/O module uses DHCP to obtain an IP address and connect to a network. If no DHCP server is
available, the I/O module times out and binds to a link-local IP address. The I/O module can also be configured
with a static IP address.
l
The I/O module connects to the first supported In-Sight vision system that requests a connection.
l
A connection to the I/O module can come from a supported In-Sight vision system connected directly to the I/O
module using the PoE port or from the network to which the I/O module is connected via the LAN port.
l
The connection between the I/O module and the vision system is maintained when power is cycled.
Configure the I/O Module
Using In-Sight Explorer, you can modify the I/O module’s host name and configure the network settings using the
Spreadsheet View or EasyBuilder View. For more information, refer to the
In-Sight
®
Explorer Help
file, which is available
from the Help menu or by pressing the F1 key.
Configure the Vision System
Using In-Sight Explorer, you can configure the vision system to use the In-Sight CIO-MICRO and CIO-MICRO-CC I/O
module. For more information, refer to the
In-Sight
®
Explorer Help
file, which is available from the Help menu or by
pressing the F1 key.
25
Installation