4. Set the
Time between Trigger Start and the Synchronized Acquisition Timestamp
. This is the time the Primary
Reader adds to the trigger to make sure all devices already received the trigger message before this time stamp
(Primary Reader Only).
5. Set the
Local Offset Added to the Synchronized Acquisition Timestamp
. This is the time the Secondary
Reader adds to the timestamp to realize offset image acquisitions (Secondary Reader Only).
Note
: The DataMan 360 readers use IEEE1588 for high-speed trigger synchronization.
Note
: Multi-Reader Sync is only available in DataMan 360 readers with an -M option. For details, see
DataMan 360 Series Tuning
By tuning, your reader automatically selects the best settings for the given reading situation, based on parameters of
illumination, camera and decoder properties, and focal distance. Tuning autodisciminates all enabled symbologies (both
1-D and 2-D). If multiple symbols are found in the field of view, tuning locks on the first one found. Use this feature to
create an optimum setting to read your codes.
You can use any of the following methods to tune your reader:
l
Press the
Tune
button at least for 3 seconds on your reader. The first press starts the tuning, and the second
press cancels the tuning, if it is still ongoing.