3. Switch to the
Standard
tab and enter text in the
Leading Text
field.
4. You can also add trailing text by entering text in the
Terminating Text
field.
Keep the following guidelines in mind as you design your system:
l
Make sure that the maximum cable length between any two DataMan 360 readers or between the PC and any
DataMan reader is no greater than 15 meters.
l
There is no fixed limit to the number of DataMan 360 readers that you can connect to a single PC. Each reader
introduces a delay of about 100 ms when it retransmits received serial data. If you have 5 readers, this means
that there will be a 400 ms delay between the time the first reader in the chain transmits data and the PC receives
it.
l
Each DataMan 360 reader must receive a hardware trigger signal on its Input 0 line. You can wire the input ports
to a common trigger signal or you can provide individual triggers for each reader.
l
Each DataMan 360 reader must be individually configured for multi-port operation, and you must perform this
configuration using a USB connection.
l
If
any
reader in the multi-port chain loses power or becomes disconnected, then no data from any other reader
will be transmitted.
l
If a DataMan 360 is transmitting its own read result, it will buffer any data received from another reader until it has
finished its own data transmission. If a DataMan 360 is transmitting another reader’s data, it will buffer its own
data if it receives a trigger signal while it is processing the other reader’s data.
l
If you use a single power supply for multiple readers, make sure that the power supply can provide enough
power for all of the readers.
65