4. Place the
DM360-HPIL-RE-01 or DM360-HPIL-RE-P-01
unit on the front of the device.
CUSTOMIZED CAPTIVE SCREW, PHILLIPS PAN HEAD, M3x28mm
Note
: The minimum peak current capacity of the power supply for the device and the DM360-HPIL-RE-01 /
DM360-HPIL-RE-P-01 is 2.2A per unit.
Note
: The DM360-HPIL-RE-01 or DM360-HPIL-RE-P-01 is also compatible with the 10.3 mm Liquid Lens.
For the 10.3 mm Liquid Lens, use CUSTOMIZED CAPTIVE SCREW, PHILLIPS PAN HEAD, M3x28mm.
5. Screw in the four screws.
Note
: Use 0.2 Nm torque on the screws and tighten in sequence.
Installing a C-Mount Lens
1. Remove the lens plug as described in
2. Thread the lens into the reader.
3. Place the reader at the desired working distance from focus target.