Mount the backplate using countersunk headed screws adjacent to the opening edge
of the door.
If fixing hole ’A’ is used then the breakout must be removed and the screw must not
protrude.
Feed the required cables through the backplate:
·
The cable from the controller.
If wall tamper function is to be used then breakout ‘B’ must be removed and an
appropriate wall screw fitted through the hole to actuate the tamper lever.
2
1
Mount the Backplate
Reader Connections
The S884-OSDP reader is a
keypad. The reader is configured for RS485 / OSDP communications.
This reader is for indoor Use Only.
The S884-OSDP reader will read smartMAX encoded MIFARE cards and card
serial numbers from most ISO 14443A smart cards which have a 4-byte UID (User
Identification).
For additional information regarding the installation, configuration and proper use of
this product:
SMS User Guide, P/N 9600-0429,
M2150 Access Control Design Guide, P/N 9600-0420,
M2150 Intrusion Guide, P/N 9600-0540,
M4000 Commissioning Guide
contactless smart-card reader, with Graphic LCD and
, P/N 9600-0698
The securing screws ‘C’ are integral to the backplate and are unscrewed via
the small holes in the enclosure so that the screw heads locate in the
counterbored holes on the inside of the enclosure.
You should find
that the
backplate has
holes for
connection to
most standard
electrical
backboxes.
C
A
B
Installation and User Instructions for S884 OSDP Readers
0V
Rx+
Rx-
12V
Controller
0V
0s
+V
RS485 (OSDP)
1s
Reader
TB1
Connect shield at
controller end only.
Slide the ferrite sleeve onto cable before wiring terminal block. Ferrite to be placed 50mm (2") up cable and held in place
with cable ties.
Note:
The
FERRITE
must be fitted!
Note:
1). Consult local AHJ (Authority Having Jurisdiction) when installing access control readers and locking mechanisms to any
portal in an egress path.
2). The use of Fail Closed / secure configuration shall be determined by local building codes and the local AHJ.
3). Wiring methods shall be in accordance with NEC (National Electrical Code) ANSI/NFPA 70.
225ft (75m) max with Belden 9503 or
450ft (150m) by doubling power cores
with Belden 9536.
If termination is required use Lk5 to set
(see over).
Twisted
pairs