7.3 Warning
safety chain
When hanging the
Panorama Cyc 250 C
we recommend the use of a safety chain (cod. 069), affixed to the appropriate hole
(B) on the yoke of the
Panorama Cyc 250 C
and to the suspension device.
This secondary safety attachment should be done using either a metal wire rope or a metal chain, both suitably rated for the pur-
pose.
risk of fire
Every projector produces head, and should therefore be installed in a well-ventilated position. The minimum distance from flamma-
ble materials: 0,5m. The minimum distance from the object being illuminated: 2 m.
cabling
The mains cable provided is thermally resistant, complying to the most recent international standards.
NB:
In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø exter-
nal 10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°.
coemar
cod. CV5309).
mains connection
Panorama Cyc 250 C
can operate at voltages from
100V-115V-208V-230V-240V
at
50
or
60Hz
(operating voltage and
frequency can be selected as described in section 6 and 19 of this manual). Prior to connecting the unit to your mains supply, ensu-
re that the model in your possession correctly matches the mains supply available to you.
For connection purposes, ensure your plug is of a suitable rating:
at
230 V
: 2 Amps on startup, 1,6 amps constant draw in normal operation
a
115 V:
4,2 Amps on startup, 3,2 amps constant draw in normal operation
Locate the mains cable which exits the base of the unit and connect as shown below:
protection
The use of a thermal magnetic circuit breaker is recommended for each
Panorama Cyc 250 C
.
A good earth connection is essential for the correct operation of the fixture. Strict adherence to regulatory norms is strongly recom-
mended.
Panorama Cyc 250 C. must be earthed; never install the unit unless the yellow/green earth cable is secu-
rely connected.
massa/ground
neutro/neutral
fase/live
marrone - brown
blu - blue
giallo/verde - yellow/green
alimentazione
main
8. Mains connection
8