9.3 Synchronising Panorama Cyc 250 without DMX 512 signal.
Multiple
Panorama Cyc 250 C
units may be interconnected in the absence of
DMX 512
signal, operating simply via the inbuilt
programs within the
Panorama Cyc 250 C
.
All
Panorama Cyc 250 C
s
thus connected will operate simultaneously
with one unit acting as MASTER and all subse-
quent units as a SLAVES.
Determine which of the
Panorama Cyc 250 C
will act as master, usually by the criterion of ease of access:
coemar
code for the IP 67 rated XLR3 socket is ME 34
coemar
code for the IP 67 rated XLR3 plug is ME 35
Connection should be to international standards:
pin 1= gnd
pin 2= data –
pin 3= data +
Ensure that all data conductors are isolated from one another and the
metal housing of the connector.
Pin 1 should never be connected to mains power.
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
made in italy by
coemar
spa
Castel Goffredo (mn)
Attenzione!
Alta tensione all'interno dell'apparecchio. Togliere
tensione prima di effettuare qualsiasi operazione.
Una buona connessione di terra e' essenziale.
Contenitore molto caldo. Non installare su alcuna
superficie infiammabile. Distanza minima da
materiale infiammabile: 0,5m. Prima di accendere
l'apparecchio e' indispensabile leggere il manuale
di istruzioni; importanti
informazioni di
sicurezza.
Warning!
High voltage inside.
Caution: hot lamp. Disconnect
from power supply before opening.
A good ground connection is essential.
Case is very hot. Do not install on flammable
surfaces. Min. Distance from flammable materials
to all exterior surfaces:0,5m. Important safety
information, see instruction manual before use.
DMX OUT
DMX IN
230v
ie max: 2A
ie: 1,6A
max temp ext:
150
°
C
ta max:
35
°
C
cos
ϕ:
0,85
IP 44
2 m
2 m
alto/top
115v
ie max: 4,2A
ie: 3,2A
Weight: Kg 16,5
factory set
main at:
100V
115V
208V
230V
240V
50Hz
60Hz
made in italy by
coemar
spa
Castel Goffredo (mn)
Attenzione!
Alta tensione all'interno dell'apparecchio. Togliere
tensione prima di effettuare qualsiasi operazione.
Una buona connessione di terra e' essenziale.
Contenitore molto caldo. Non installare su alcuna
superficie infiammabile. Distanza minima da
materiale infiammabile: 0,5m. Prima di accendere
l'apparecchio e' indispensabile leggere il manuale
di istruzioni; importanti
informazioni di
sicurezza.
Warning!
High voltage inside.
Caution: hot lamp. Disconnect
from power supply before opening.
A good ground connection is essential.
Case is very hot. Do not install on flammable
surfaces. Min. Distance from flammable materials
to all exterior surfaces:0,5m. Important safety
information, see instruction manual before use.
DMX OUT
DMX IN
230v
ie max: 2A
ie: 1,6A
max temp ext:
150
°
C
ta max:
35
°
C
cos
ϕ:
0,85
IP 44
2 m
2 m
alto/top
115v
ie max: 4,2A
ie: 3,2A
Weight: Kg 16,5
out
out
in
master
slave
in
Ad altri
Panorama C
yc
250 C.
(slave)
Connect to other
Panorama C
yc
250 C.
(slave)
10