Chapter 5: Installation check and test
82
Test the system with SAILOR 6018
4. Test the
Inmarsat C
Distress buttons on the connected units and on
the SAILOR 6018 by pushing them as you would in a real Distress
situation.
The light and buzzer in the Distress buttons should work the same way
as in a real Distress situation. For details on the Distress buttons, see
SAILOR 6120/30/40/50, User manual
[1].
5. When you have finished testing, or you need to send a real Distress
alert, click
Cancel
in the
Test in progress
window.
Note
Before pushing any Distress buttons, check the units as
follows:
• If an alarm panel is connected to the SAILOR 6018: On the
alarm panel, make sure the display shows “Test” next to the
Inm C unit that is active (marked with a bullet), before
pushing the
Inm-C Distress
button.
• On the SAILOR 6018, make sure the display shows “Test in
progress” before pushing the
Distress
button on the
SAILOR 6018.
Important
Only
Inmarsat C
Distress buttons connected to the
system under test are included in this test.
Do not
push
any other Distress buttons, unless it is a Distress
situation!