All content © 2018, cmotion GmbH. All specifications are subject to change without further notice.
http://www.cmotion.eu
page 58 of 80
6.2.3.4.2.4. Ramp
The ramp menu allows you to adjust the start and stop acceleration of the motor to min,
short, long and max. This allows for both smooth speed-up and slow-down curves.
NOTICE
The motor settings menu can be reached from all motors main screens quickly by tapping and
holding the touch display or by pressing and holding menu button 2 (MB2).
6.2.3.4.2.5. Calibrate
The calibrate menu allows you to calibrate each motor axis individually. Selecting calibrate
will calibrate the corresponding lens motor without confirmation required.
NOTICE
The lens motors must be recalibrated under the following conditions:
- When a motor is detached from the lens
- After changing motors
- After changing lenses
- After a change in a motor position while powered down
NOTICE
Omitting motor calibration might lead to damage of the lens due to the high level of motor
torque!
CAUTION!
Risk of injury! Do not touch the motor gear while motor is powered up!
This device is not intended for use by children. Keep body parts out of the motion path.
Disconnect the plug if the device is not used for a longer period of time.
IEC 60417-6056 (2011-05) for other moving parts
6.2.3.4.3.
Stealth mode
The stealth mode menu can activate and deactivate the cPRO’s stealth mode. When
stealth mode is on, the illumination of all LBUS connected cforce motors will be turned off
(e.g. if the camera angle is critical because of camera reflection in the picture).