26
Faults Menu
IQ DISPLAY MODULE (IQDM) AND IQDM-P
DIAGNOSTICS: EXCEL SYSTEM WITH
ERIC CHARGING
What it means:
This is a symptom, not a cause. The controller records the number of times this occurs.
What to do:
Charge batteries. If fault occurs more frequently than normal, test battery pack. See Section 30 –
Batteries: Electric Vehicle with ERIC Charging.
MAIN WELDED
If the speed controller detects that the solenoid contacts are welded closed, a
main welded
fault is detected.
What it means:
The solenoid contact is welded closed and will not dropout when pedal is released, or key switch
is turned to OFF, or FNR is switched to N.
What to do:
Replace solenoid. If vehicle continues to operate at half speed, check accessory wiring.
HIGH SPEED WALKAWAY
If the controller receives a signal to activate walk away braking while the vehicle is moving at a speed greater than 2
mph (3.2 km/h), the controller registers a
high speed walkaway fault
.
What it means:
This is a symptom, not a cause. The key switch was turned to OFF while the vehicle was coasting
faster than 2 mph (3.2 km/h).
What to do:
Most likely, this is due to driver error. If not, check speed sensor on motor and key switch for proper
operation.
SPEED SENSOR
If the speed controller does not detect pulses from the speed sensor while the controller outputs power (greater than
75% armature PWM) to the motor, a
speed sensor
fault is detected.
What it means:
Speed sensor is not working. Check connection.
What to do:
Replace speed sensor.
MAIN DRIVER ON
If the FET that controls the closing of the solenoid contacts is found to be energized when it should not be, a
main
driver on
fault is detected by the speed controller.
What it means:
The controller FET controlling the energizing of the solenoid is on (or energized) when it should not
be. This causes main contactors to stay engaged. Pin 12 provides ground for the solenoid coil when FORWARD,
REVERSE, KEY, or FOOT INPUT is present at the controller. If the ground continues to be present once either KEY,
FOOT, FORWARD or REVERSE INPUT is removed,
main driver on
is detected.
What to do:
Replace controller.
MAIN COIL OPEN
If the speed controller determines that the solenoid is not closing as a result of a solenoid coil failure, a
main coil
open fault
is detected.
What it means:
An open circuit in the solenoid coil. It could be in either the ground side or B+ side of the circuit.
What to do:
Check for a broken or disconnected blue wire on the B+ side of the solenoid coil, a broken or disconnected
blue/white wire on the B- side of the solenoid coil, a broken coil wire inside the solenoid which would result in zero
ohms resistance reading, a defective coil which could result in very low coil resistance (usually less than 40 ohms;
large solenoids should read 180 to 190 ohms; small solenoids 200 to 250 ohms), a broken blue/white wire at the 16-pin
controller plug or its terminal is loose in the 16-pin plug.
Page 26-14
2014 Precedent
®
Golf Car Maintenance and Service Manual
Summary of Contents for Precedent 2014
Page 2: ......
Page 4: ......
Page 24: ......
Page 28: ......
Page 38: ......
Page 66: ......
Page 104: ......
Page 116: ......
Page 152: ......
Page 234: ......
Page 252: ......
Page 264: ......
Page 298: ......
Page 332: ......
Page 394: ......
Page 412: ......
Page 438: ......
Page 444: ......
Page 508: ......
Page 534: ......
Page 543: ......
Page 544: ......
Page 545: ......
Page 547: ......
Page 548: ......