BATTERIES: ELECTRIC VEHICLE WITH
POWERDRIVE CHARGER
Battery Testing – 8 Volt
15
EXAMPLE OF A HYDROMETER TEST
CORRECTED SPECIFIC GRAVITY
VEHI-
CLE
NO.
BAT-
TERY
NO.
ELEC-
TROLYTE
TEMPERA-
TURE
CORREC-
TION
FACTOR
CELL 1
CELL 2
CELL 3
CELL 4
REQUIRED
ACTION
12
1
20 °F (-6.6 °C)
– 0.024
1.275 –
0.024 =
1.251
1.280 –
0.024 =
1.256
1.280 –
0.024 =
1.256
1.280 –
0.024 =
1.256
Strong Battery
– Fully Charged
35
6
90 °F (32.2 °C)
+ 0.004
1.155 +
0.004 =
1.159
1.165 +
0.004 =
1.169
1.160 +
0.004 =
1.164
1.165 –
0.004 =
1.169
Discharged
Battery –
Recharge
54
3
50 °F (10 °C)
– 0.012
1.260 –
0.012 =
1.248
1.200 –
0.012 =
1.188
1.270 –
0.012 =
1.258
1.270 –
0.012 =
1.258
Bad no. 2 Cell
69
5
80 °F (26.7 °C)
0.000
1.250 – 0 =
1.250
1.255 – 0 =
1.255
1.230 – 0 =
1.230
1.250 – 0 =
1.250
Weak no. 3
Cell – Catch-up
Charge
38
2
100 °F (37.8 °C)
+ 0.008
1.200 +
0.008 =
1.208
1.180 +
0.008 =
1.188
1.170 +
0.008 =
1.178
1.180 +
0.008 =
1.188
Discharged
Battery –
Recharge and
Recheck
22
4
80 °F (26.7 °C)
0.000
1.240 – 0 =
1.240
1.245 – 0
= 1.245
Float does
not rise
1.250 – 0 =
1.250
no.3 Cell Dead
– Replace
Battery
2014 Precedent
®
Golf Car Maintenance and Service Manual
Page 15-5
Summary of Contents for Precedent 2014
Page 2: ......
Page 4: ......
Page 24: ......
Page 28: ......
Page 38: ......
Page 66: ......
Page 104: ......
Page 116: ......
Page 152: ......
Page 234: ......
Page 252: ......
Page 264: ......
Page 298: ......
Page 332: ......
Page 394: ......
Page 412: ......
Page 438: ......
Page 444: ......
Page 508: ......
Page 534: ......
Page 543: ......
Page 544: ......
Page 545: ......
Page 547: ......
Page 548: ......