Unit 1, 10 Duerdin St, Clayton VIC 3168, Australia
Tel: +61 3 9239 8088 Fax: +61 3 9239 8024
E-mail: [email protected] www.clenergy.com.au
15
page
of 25
Installation Instruction
Step 4 When using as an Inter Clamp, click the
Universal Clamp into the rail channel and slightly lift
the framed PV Module to ensure the Grounding Clip
is fully covered as shown in the figure on the right
Step 5 Loosely place the next framed PV Module
into the other side of the Universal Clamp. Ensure
the Grounding Clip is fully covered and ensure the
frame of the PV Module is in close contact with
Universal Clamp as shown in the figure on the right.
Step 6 Repeat steps above to install all PV Modules.
Visually check the Universal Clamps and PV
modules are properly positioned and then fasten all
Clamps.
When you using Universal Clamps, the gap
between two adjacent PV Modules is 20mm.
The recommend torque for Universal Clamps in the
End Clamp position is 13~14N.m.
The recommend torque for Universal Clamps in the
Inter Clamp position is 16~20N.m.