![Clenergy PV-ezRack SolarRoof Series Planning And Installation Manual Download Page 37](http://html1.mh-extra.com/html/clenergy/pv-ezrack-solarroof-series/pv-ezrack-solarroof-series_planning-and-installation-manual_2622553037.webp)
Project: CL-10088-SM-REV-C
Client: Clenergy Australia
PV-ezRack
Engineering Certificate
ER-R-ECO (ECO Rail)
ER-I-05 (Tin Interface)
2 m x 1 m
2
1.5 mm
A
B
C
D
1386
578
532
459
413
376
349
863
707
597
615
1561
1469
PV ez-Rack SolarRoof Interface spacing Table for Tin Roof
Type of Rail
Type of Interface
Solar Panel Dimension
Terrain Category
Purlin Thickness
Roof Angle - 30° <
α
< 60°
Note: This Engineering report is based on 2 m x 1 m panels and two rails per panel. Refer to Note 12 for
further details.
1359
1331
1102
1010
936
872
Wind
Region
Building Height (m)
H < 5
5 < H < 10
10 < H < 15
15 < H < 20
20 < H < 30
1423
Note: The above spacings are for Up Wind End and Down Wind End Zone. Refer to Note 20 for Central
Zone spacings (10% increase).
Final Copy
11/12/2019
10