background image

Connecting the touch screen via LAN

The touch screen can be connected to the following codecs via LAN. The codec 

may be part of a Profile system.

• 

Codec C20

• 

Codec C40

• 

Codec C60

• 

Codec C90

Check the system information page on your codec to make sure its software 

version is TC4.1 or later. If not, contact your Cisco representative. 

1. 

Restart the codec before you proceed with the installation.

2. 

Connect the touch screen cable to the Power adapter. 

3. 

Connect the shielded Ethernet cable between the Power adapter and the LAN 

(Ethernet) socket.

4. 

Connect the supplied power cable between the Power adapter and the power 

socket. Once power is connected, the touch screen start-up procedure begins. 
Wait while the touch screen initializes. Continue when the 

Select codec to pair 

with

 window appears. This may take a few minutes. 

Note: 

The touch screen obtains its IP settings automatically from the network 

(DHCP). In most cases this is preferred and you can continue with the pairing. 
If you need a static IP address for your touch screen perform the steps described in 

the 

Change the IP settings

 section, before continuing. 

7.5 m

5 m

Power 

adapter

Power socket

LAN socket 

(Ethernet)

1.8 m

A list of all codecs that are in Pairing mode is displayed on the touch screen. 

5. 

Click the codec name in the list.

Note: 

If your codec is not in the 

list, read about 

What to do if your 

codec is not listed

 below.

6. 

Review codec details and click  

Start Pairing

 to start the pairing 

process.

7. 

If required, the touch screen  

downloads and installs new  

software from the codec. The 

touch screen automatically 

restarts after the software 

upgrade. This process may take a 

few minutes.
If your codec is password 

protected, you will be prompted 

for an administrator username 

and password to sign in to the 

codec. 
Continue when the menu and 

contact list appear on the touch 

screen.

8. 

Verify that the touch screen is successfully paired to your codec by checking the 

codec address displayed in the top banner.

The touch screen is ready to use.

Refresh list

Select codec to pair with

Select codec manually...

IP Settings

System name (Codec type)

[email protected]

The touch screen 

menu and contact list

Available

[email protected]

12:00

[email protected]

Product:

Cisco TelePresence System Codec

SIP URI:

[email protected]

H323 id:

[email protected]

Software:

TC4.1.0

IP address:

192.168.1.128

Serial number:

CBA123456789

System name (Codec type)

[email protected]

Start Pairing

Back

This box contains: 

• 

Cisco TelePresence Touch with cable (7.5 m / 25 ft)

• 

Power adapter

• 

Power cable (1.8 m / 6 ft) (included when Touch is shipped as a stand-alone unit)

• 

Shielded Ethernet cable (5 m / 16 ft) 

• 

Cleaning cloth 

Compatibility

The touch screen is used with the Cisco TelePresence Codec C Series. These 

codecs are also used in the Cisco TelePresence System Profile series. The touch 

screen can be installed in two ways:

A. 

Connecting the touch screen to a codec via LAN (local area network).

B. 

Connecting the touch screen directly to the codec.

Note: 

The codec software version must be TC4.1 or later.

Safety requirement

You have to use a shielded Ethernet cable (as supplied).

User documentation

User documentation for Cisco TelePresence products, including compliance and 

safety information, is found on 

http://www.cisco.com/go/telepresence/docs

78-19948-01 JANUARY 2011. 

Copyright © 2010-2011 Cisco Systems, Inc. All rights reserved.

Cisco TelePresence Touch

For C Series

iNstALLAtioN guide