22
Revision date: 02.07.12
CLEARSPAN
™
POLY BUILDINGS
Complete these steps to install the conduit and strapping
for the stretch pockets of the main cover.
1. Take the first section of PVC conduit and feed it into the
stretch pocket from the bottom at one end of the cover.
Insert the plain end of the conduit into the pocket so the
next section can be joined to the first.
Photo above shows a similar cover and the location of the stretch
pocket. Cover is shown with the underside, which is the side
visible from inside the frame when the cover is installed, facing up.
Photo shows the notched stretch pocket and the installed
PVC conduit at the end of a similar main cover.
2. Once the bell end reaches the pocket, take another
section of PVC conduit, insert the plain end into the bell
end of the previous section and secure the joint using a
Tek screw.
Notched Stretch Hem
NOTE:
Some covers
may not ship with the
pocket material removed
for the installation of the
straps. If slots need to
be created, cut only the
cover pocket;
do not cut
the main cover
.
Space slot 18" to 24"
apart on-center if these
need created.
PVC Conduit
3. Wrap the Tek screw and joint using duct tape.
4. Repeat the steps and continue to assemble and feed
the PVC conduit into the pocket.
5. Once the PVC conduit is fully assembled, secured at
the joints, and inserted into the pocket, repeat the steps
for the remaining end of the main cover.
6. With both PVC conduits assembled and installed, verify
that the cover is centered on the frame and move to
one end rafter.
7. Cut six (6) sections of the 2" strap from the bulk roll that
are long enough to tie the PVC conduit to the end rafter
in evenly spaced locations.
INSTALL PVC CONDUIT (CONTINUED)
Dashed lines show
the temporary straps
(Step 7) tied between
the PVC conduit and
the top of the end
rafter to keep the
main cover centered
on the frame during
the installation of the
strapping at the other
end of the frame.
End Rafter
PVC conduit in
notched pocket
Notched Stretch
Hem Pocket
End of main cover
where bonnet strap
is located.
Sample Main
Cover to show
pocket location.
Summary of Contents for 106786
Page 26: ...26 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS FRONT PROFILE ...
Page 27: ...27 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS CONNECTIONS ...
Page 30: ...30 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS BASE DETAILS ...
Page 31: ...31 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106786 ...
Page 32: ...32 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106787 ...
Page 33: ...33 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106788 CABLE ENDS HERE ...
Page 34: ...34 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106789 ...
Page 35: ...35 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106790 ...
Page 36: ...36 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS SIDE PROFILE 106791 ...
Page 37: ...37 Revision date 02 07 12 CLEARSPAN POLY BUILDINGS THIS PAGE RESERVED FOR CUSTOMER NOTES ...