We,
Cleanfix Reinigungssysteme AG
Stettenstrasse - CH-9247 Henau
declare under our sole responsibility that the product,
Water suction cleaning appliane
TW 411 / TW 412
from serial code No. 9001 and following
(name,type, serial number)
to which this declaration relates is in
conformity with the following stand- ard(s) or other
normative document(s).
Sefety:
EN 60335-1 (ed.4) ; am 1; am 2;
EN 60335-2-68 (ed.3) ; am1; am 2
EMC:
CISPR 14-1 (ed.5) ; am1
CISPR 14-2 (ed.1) ; am1; am 2
EN 61000-3-2 (ed.3) ; am1; am 2
EN 61000-3-3 (ed.2)
EMF:
IEC 62233 (ed.1)
( title and/or number and date of issue of the standard(s) ).
following the provisions of Directive
2006 / 95 / EC - 2004 / 108 / EC - 2006 / 42 / EC
Henau, 01.01.2010
Roland Flück
Environmental protection
Declaration of Conformity
The packaging material can be recycled.
Please do not throw the packaging
material into household waste; please
send it for recycling.
Old appliances contain valuable materi-
als that can be recy-cled; these should
be sent for recycling.. Batteries, oil, and
similar substances must not enter the
environment. Please dispose of your old
appliances using appropriate collection
systems.
English 9
6
Maintenance / servicing
6.1 Daily servicing:
☞
Drain the fresh watertank. Fill with approx. 6l of fresh
water. Hold the nozzle over a réceptacle and flush the
pressure pump, hose and spray nozzles thoroughly.
Clean float and fresh water filter (on tank base). Drain
fresh water tank completely.
☞
Drain waste water tank completely and thoroughly
wash out with clean water.
☞
Wipe machine dry inside and out.
6.2 Repairs and maintenance:
☞
The motors and pressure pump are maintenance-free.
☞
We recommend our Service for repairs and
inspections.
☞
Protect machine and accessories from frost.
7
Faults
7.1 Possible causes of insufficient spraying
capacity:
☞
Spray nozzles blocked
☞
Fresh water filter dirty
☞
Fresh water tank empty
☞
Pressure pump not switched on
7.2 Possible causes of low suction capacity:
☞
Transparent dome not correctly mounted to waste
water tank aperture (air entering)
☞
Suction slot on nozzle blocked
☞
Suction hose not correctly connected to handpipe
☞
Waste water tank full (float at top is interrupting
suction)
☞
Riser tube mesh blocked
8.
Final remark
Subject to changes within the framework of technical
progress!!