1.6 Working method
The steam temperature at the exhaust of the
nozzle is approx. 100°C. When cleaning
heat-sensitive materials do not remain under a
minimal distance of 2-5!
1.7 Lack of water during the operation
☞
The red water check lamp (9) blinks when the fresh
water tank/boiler is empty. The heating is switched-off
automatically.
Procedure:
☞
Switch-off the yellow switch (10) for heating.
☞
And continue working while the
rest use up steam.
☞
Switch-off red main switch (12).
☞
Unplug the machine from the
mains.
☞
Slowly unscrew the security cover
from the clean water filling hole
and let the rest steam escape.
☞
Tap water (10-60 ° C) and refill plug the power cord,
as
described
in
item
1.5
to
function.
Never open the security cover of the fresh water
filing opening as long the machine is under
steam
pressure.
Danger
of
scalding!!
2. Maintenance
2.1 Safety instructions
☞
When cleaning and servicing the machine or changing
parts, pull the mains connector plug.
☞
The machine must not be cleaned with high pressure
steam cleaners or powerful liquid jets.
☞
For reparations use only original spare parts.
Before commencing any maintenance work,
switch of the machine and unplug it from the
mains.
3. Repair
We recommend that repairs and inspections are carried out
by an authorised service agent.
3.1 Emptying waste water
After using the machine, completely drain the waste water
tank and rinse thoroughly with clean water.
Procedure:
☞
Push the ball on the discharge hose to the side and
let the waste water drain into a bucket or a floor
drain.
☞
Tightly close the ball again.
3.2 Emptying the fresh water
After finishing work, drain the fresh water. When the
machine has cooled off, open the drain screw (16, page 2)
at the bottom of the machine with a tool, let water and lime
residues drain. Close the drain screw lightly.
9
Commissioning, operation
3.3 Decalcifying the fresh water tank/boiler
With Disinfectant Cleaner (1:1 with water), depending on
water hardness descale from time to time. Then rinse with
fresh water. Steam cleaner should not be heated be.
4. Troubleshooting
4.1 Weak suction:
☞
Suction tube, hose or nozzle clogs?
☞
Waste water tank cover on the waste water tank not
correctly positioned (secondary air)?
☞
Filter of suction pipe in the waste water tank cover
abstructed?
☞
Ball of drain hose not properly closed?
4.2 Inadequate development of steam
☞
Heating switch off?
☞
Heating check lamp still alight, working temperature
not yet reached?
The suction motor of the steam vacuum cleaner DS 8 is
equipped with a thermal overload switch, which shuts-off
the motor automatically if it overheats.
5. Storage
If the steam cleaner is not used, this is is cool and dry at
normal room conditions (not under 0 ° C) to be stored.
6.
Environmental protection
10
12
9
DS 8 - Englisch
The packaging material can be recycled.
Please do not throw the packaging
material into household waste; please
send it for recycling.
Old appliances contain valuable materi-
als that can be recy-cled; these should
be sent for recycling.. Batteries, oil, and
similar substances must not enter the
environment. Please dispose of your old
appliances using appropriate collection
systems.