CLARKE
1-33
ENCORE MAX
SOLUTION
TANK
RECOVERY
TANK
SOLUTION
CONTROL
VALVE
SCRUB
BRUSH
SQUEEGEE
FLOOR
CONTACT
STRAINER
SOLUTION
PUMP
STRAINER
ESP OPERATING MODEESP OPERATING MODE
During the scrubbing process, filtered water from the solution tank is fed to the solution line and then to the
floor where two disc scrubbing brushes work to dislodge soil. After scrubbing, the dirty solution is vacuumed
from the floor and discharged into the recovery tank. At intervals, a float switch activates the recycling pump,
which sends filtered solution from the recovery tank to the solution tank.
OPERATING INSTRUCTIONS
Fig. 33