ci5000 Series Printer Technical Service Manual
Version 0.1
6-42
Corrective Action:
1. Ensure the fan is operating.
2. Ensure the Air filter is not clogged (replace if needed). For replacement procedure see Section 6
Sub-
section “Replace/Clean Air Filter”
3. Ensure the Sensor is not laying on any board components. The sensor needs to be freestanding
as shown in the picture above.
Temperature Fault
–
CPU TEMP SENSOR SHORTED
Definition:
The temperature signal on the CPU board has been shorted. The printer will shut down automatically
and this error/fault will be displayed. The sensor is part of the CPU board and is non-field repairable.
Corrective Action:
Replace the CPU board (see page
xx.xx
CPU Board replacement procedure)
Temperature Fault
–
CPU TEMP SENSOR OPEN
Definition:
The temperature signal on the CPU board has an electronic open. The printer will shut down
automatically and this error/fault will be displayed. The sensor is part of the CPU board and is non-field
repairable.
Corrective Action:
Replace the CPU board (see page
xx.xx
CPU Board replacement procedure)
Ink Reservoir Empty
Summary of Contents for ci5200
Page 34: ...ci5000 Series Printer Technical Service Manual Version 0 1 1 28 Ink System Diagram ...
Page 47: ...ci5000 Series Printer Technical Service Manual Version 0 1 2 10 ...
Page 129: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 6 Encoder ...
Page 130: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 7 Beacon Options ...
Page 132: ...ci5000 Series Printer Technical Service Manual Version 0 1 4 9 ...
Page 189: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 45 Pic 3 Pic 4 Ink Reservoir Low ...
Page 222: ...ci5000 Series Printer Technical Service Manual Version 0 1 6 78 ...
Page 286: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 5 Electrical Connections ...
Page 287: ...ci5000 Series Printer Technical Service Manual Version 0 1 11 6 Fluids Connections ...