Citrix ADC MPX
• RS232 serial Console Port.
• 10/100Base-T copper Ethernet Port (RJ45), also called the LOM port. You can use this port to
remotely monitor and manage the appliance independently of the Citrix ADC software.
• Two 10/100/1000Base-T copper Ethernet Management Ports (RJ45), numbered 0/1 and 0/2 from
left to right. These ports are used to connect directly to the appliance for system administration
functions.
• Network Ports. Twelve copper or fiber 1G SFP ports and twenty-four 10G SFP+ ports.
The following figure shows the back panel of the MPX 24100/24150 appliances.
Figure 2. Citrix ADC MPX 24100/24150, back panel
The following components are visible on the back panel of the MPX 24xxx appliances:
• Non-maskable interrupt (NMI) Button, used at the request of Technical Support to initiate a core
dump. To press this red button, which is recessed to prevent unintentional activation, use a pen,
pencil, or other pointed object. The NMI Button is also available remotely over the network in
the LOM GUI, in the Remote Control menu.
• System status LED, which indicates the status of the appliance, as described in
.
Note
: On an
MPX 24100/24150 appliance running LOM firmware version 3.22, the system status LED indicates
an error (continuously glows RED) even though the appliance is functioning properly.
• Four power supplies, each rated at 750 watts, 100-240 volts. A minimum of two power supplies
are required for proper operation. The extra power supplies act as backup. Each power supply
has an LED that indicates the status of the power supply, as described in
.