Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
Chapter 3 Maintaining the System
Installing or Replacing System Components
Replacing HDDs or SSDs in the Internal Drive Compartment
This section contains the following topics:
•
Internal Drive Population Guidelines, page 3-18
•
Identifying a Faulty Internal Drive, page 3-19
•
Replacing Internal Drives, page 3-20
Internal Drive Population Guidelines
The system has 56 internal drive bays in the main chassis.
shows the internal drive bay
numbering. When populating internal drives, follow these guidelines:
•
Populate HDDs starting from the lowest-numbered bays to the highest. Populate row 1 – 14, then
row 15 – 28, and so on.
•
Populate internal SSDs starting from the highest-numbered bays to the lowest. Populate bay 56, then
bay 55, and so on.
For example, a system with 36 HDDs and 2 SSDs should have the HDDs in bays 1 – 36 and the SSDs
in bays 56 and 55.
•
The four colored boxes shown in
represent the four power groups in which power is
distributed to the drive bays.
Figure 3-7
Internal Drive Bay Numbering
353451
HDD01
HDD02
HDD03
HDD04
HDD05
HDD06
HDD07
HDD08
HDD09
HDD10
HDD11
HDD12
HDD13
HDD14
HDD15
HDD16
HDD17
HDD18
HDD19
HDD20
HDD21
HDD22
HDD23
HDD24
HDD25
HDD26
HDD27
HDD28
HDD29
HDD30
HDD31
HDD32
HDD33
HDD34
HDD35
HDD36
HDD37
HDD38
HDD39
HDD40
HDD41
HDD42
HDD43
HDD44
HDD45
HDD46
HDD47
HDD48
HDD49
HDD50
HDD51
HDD52
HDD53
HDD54
HDD55
HDD56
FAN
1,2
FAN
3,4
FAN
5,6
FAN
7,8