16-102
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 16 DLPs H1 to H99
Step 8
Click the profile name(s) you want to delete in the
Profile Names list.
Step 9
Click
OK
.
Step 10
Click
Yes
in the Delete Alarm Profile dialog box.
Note
If you delete a profile from a node, it still appears in the network view
Provisioning > Alarm Profile Editor window unless you remove it using the following step.
Step 11
To remove the alarm profile from the window, right-click the column of the profile you deleted and
choose
Remove
from the shortcut menu.
Note
If a node and profile combination is selected but does not exist, a warning appears: “One or more
of the profile(s) selected do not exist on one or more of the node(s) selected.” For example, if
node A has only profile 1 stored and the user tries to delete both profile 1 and profile 2 from node
A, this warning appears. However, the operation still removes profile 1 from node A.
Note
The Default and Inherited special profiles cannot be deleted and do not appear in the Select
Node/Profile Combination for Delete Window.
Step 12
Return to your originating procedure (NTP).
DLP-H84 Enable Alarm Filtering
Step 1
At the node, network, or card view, click the
Alarms
tab.
Step 2
Click the
Filter
tool at the lower-right side of the bottom toolbar.
Alarm filtering is enabled if the tool is selected and disabled if the tool is raised (not selected).
Alarm filtering will be enabled in the card, node, and network views of the Alarms tab at the node and
for all other nodes in the network. If, for example, the Alarm Filter tool is enabled in the Alarms tab of
the node view at one node, the Alarms
tab in the network view and card view of that node will also show
the tool enabled. All other nodes in the network will also have the tool enabled.
If you filter an alarm in card view, the alarm will still be displayed in node view. In this view, the card
will display the color of the highest-level alarm. The alarm is also shown for the node in the network
view.
Purpose
This task enables alarm filtering for alarms, conditions, or event history in
all network nodes.
Tools/Equipment
None
Prerequisite Procedures
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Retrieve or higher
Summary of Contents for ONS 15310-MA SDH
Page 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Page 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Page 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...