3-12
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 3 Turn Up a Node
Before You Begin
Stop. You have completed this procedure.
NTP-H25 Set Up SNMP
Step 1
Complete the
“DLP-H29 Log into CTC” task on page 16-43
at the node where you want to set up SNMP.
If you are already logged in, continue with Step 2.
Step 2
In node view, click the
Provisioning
>
SNMP
tabs.
Step 3
In the Trap Destinations area, click
Create
.
Step 4
Complete the following in the Create SNMP Trap Destination dialog box:
•
Destination IP Address—Type the IP address of your network management system. If the node you
are logged into is an end ONS 15310-MA SDH network element (ENE), set the destination address
to the GNE.
Note
In ONS 15310 Software R9.0 and later, you can configure IPv6 addresses for SNMPv1/v2/v3 trap
destinations, Get/Set requests and proxy targets, in addition to IPv4 addresses.
•
Community—Type the SNMP community name. For a description of SNMP community names,
refer to the “SNMP” chapter in the
Cisco ONS 15310-MA SDH Reference Manual
.
Note
The community name is a form of authentication and access control. The community name
assigned to the ONS 15310-MA SDH is case-sensitive and must match the community name
of the network management system (NMS).
•
UDP Port—The default User Datagram Protocol (UDP) port for SNMP is 162. (More information
about provisioning the UDP port is also given in the
“DLP-H225 Set Up SNMP for a GNE” task on
and
“DLP-H226 Set Up SNMP for an ENE” task on page 18-24
•
Trap Version—Choose either SNMPv1 or SNMPv2. Refer to your NMS documentation to determine
whether to use SNMP v1 or v2.
Step 5
Click
OK
. The node IP address of the node where you provisioned the new trap destination appears in
the Trap Destinations area.
Step 6
Click the node IP address in the Trap Destinations area. Verify the SNMP information that appears in
the Selected Destination list.
Purpose
This procedure provisions the SNMP parameters so that you can use
SNMP management software with the ONS 15310-MA SDH.
Tools/Equipment
None
Prerequisite Procedures
NTP-H148 Verify Card and SFP Installation, page 3-2
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Summary of Contents for ONS 15310-MA SDH
Page 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Page 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Page 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...