18-41
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 18 DLPs H200 to H299
describes the values on the Provisioning > Line Thresholds tab for the DS-3 ports.
describes the values on the Provisioning > Elect Path Thresholds tab for the DS-3 ports.
SF BER
Sets the signal fail bit error
rate.
•
1E-3
•
1E-4 (default)
•
1E-5
SD BER
Sets the signal degrade bit
error rate.
•
1E-5
•
1E-6
•
1E-7 (default)
•
1E-8
•
1E-9
Line Type
Defines the line framing type.
•
UNFRAMED
•
M13 (multiplexed E1 to DS-3 framing)
•
C Bit (parity framing)
Line Coding
Defines the DS-3
transmission coding type.
•
B3ZS (Bipolar 3 Zero Substitution)
Line Length
Defines the distance (in feet)
from backplane connection to
the next termination point.
•
0 - 225 (default)
•
226 - 450
automaticInServi
ce Soak
Automatic in-service soak.
•
Duration of valid input signal in hh.mm after
which the port is set in service by the software.
•
0 to 48 hours, 15-minute increments.
Table 18-7
Line Options for DS-3 Ports (continued)
Parameter
Description
Options
Table 18-8
Line Thresholds Options for DS-3 Ports
Parameter
Description
Port
Port number (display only).
•
1 to 3
CV
Coding violations. Available for Near End and Far End.
ES
Errored seconds. Available for Near End and Far End.
SES
Severely errored seconds. Available for Near End and Far End.
LOSS
Number of one-second intervals containing one or more loss of signal (LOS) defects.
Available for Near End and Far End.
Summary of Contents for ONS 15310-MA SDH
Page 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Page 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Page 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...