1
0
Fabric Module 3
N77-C7706-FAB-3
ok
Xbar Sw
Hw
---
--------------
------
1
NA
0.705
Xbar MAC-Address(es)
Serial-Num
---
--------------------------------------
----------
1
NA
JAE213604M9
Chassis Ejector Support: Enabled
Ejector Status:
Top ejector OPEN, Bottom ejector OPEN, Module HW does not support ejector
based shutdown, Ejector policy disabled.
switch#
Purging the Module Configuration
You can clear the running configuration for an I/O slot that is not functioning by using the
purge module
command in EXEC mode.
This command does not work on supervisor slots nor on any I/O slot that currently has a powered-up module.
Note
Before you begin
Verify that either the I/O slot is empty or the I/O module installed in the slot is powered down.
Clear the running configuration by using the
purge module slot_number running-config
command.
Example:
switch#
purge module 1 running-config
Example
For example, suppose you create an IP storage configuration with a 48-port 10/100/1000 Ethernet
I/O module in slot 3 of Switch A. This module uses an IP address. You decide to remove this I/O
module and move it to Switch B, and you no longer need the IP address. If you try to configure this
unused IP address, you will receive an error message that prevents you from proceeding with the
configuration. In this case, you need to enter the
purge module 3 running-config
command to clear
the old configuration in Switch A before using the IP address.
Shut Down or Power Up an I/O Module
You can shutdown or power up an I/O module by using the
poweroff module
or
no poweroff module
command to specify the module by its slot number in the chassis.
Cisco Nexus 7706 Hardware Installation Guide
OL-31330-01
70
Managing the Switch
Purging the Module Configuration