Status
Color
LED
All chassis environmental monitors are reporting okay.
Green
SYSTEM
Indicates one of the following:
• At least one power supply has failed or the power supply fan has
failed.
• Incompatible power supplies are installed.
• At least one redundant fan or fan controller has failed in the
chassis. Overheating is not imminent.
Amber
Indicates one of the following:
• The temperature of the Supervisor engine has exceeded the major
threshold level.
• At least one non-redundant fan or fan controller, or both redundant,
have failed in the chassis. Overheating is imminent.
Red
The supervisor module is operational and active.
Green
ACTIVE
The supervisor module is in standby mode.
Amber
Sufficient power is available for all installed modules.
Green
PWR MGMT
Sufficient power is not available for all installed modules.
Amber
The module has detected a link.
Green
LINK
The module does not detect a link.
Off
The module is transmitting or receiving.
Flashing green
ACT
The module is not transmitting or receiving.
Off
The management port is operational.
Green
MGMT ETH
This is
available only
on
Supervisor-2E
modules.
Note
The management port link has been disabled through the software.
Amber
The management port link is bad and has been disabled due to a
hardware failure.
Flashing
amber
The module has not detected a signal.
Off
The log flash CompactFlash or USB disk is being accessed. Do not
remove the media until the LED is off.
Green
LOG FLASH
The expansion flash CompactFlash or USB disk is not being accessed.
You can remove the media while this LED is off.
Off
Cisco Nexus 7706 Hardware Installation Guide
161
OL-31330-01
LEDs