Full Redundancy
Mode
Input Source
Redundancy
Mode
Power Supply
Redundancy
Mode
Combined Mode
Power Supplies
Power Inputs
—
—
—
3,500 W
1
1 input (380 V)
3,500 W
3,500 W
3,500 W
7,000 W
2
3,500 W
3,500 W
7,000 W
10,500 W
3
7,000 W
7,000 W
10,500 W
14,000 W
4
—
—
—
3,500 W
1
1 input (220/240
V)
3,500 W
3,500 W
3,500 W
7,000 W
2
3,500 W
3,500 W
7,000 W
10,500 W
3
7,000 W
7,000 W
10,500 W
14,000 W
4
—
—
—
3,100 W
1
1 input (210 V)
3,100 W
3,100 W
3,100 W
6,200 W
2
3,100 W
3,100 W
6,200 W
9,300 W
3
6,200 W
6,200 W
9,300 W
12,400 W
4
A combination of 3-kW DC and 3.5-kW HVAC/HVDC power supplies can be used.
Note
Weights and Quantities for the Chassis, Modules, Fan Trays,
and Power Supplies
Quantity
Weight per Unit
Component
1
145.0 lb (65.8
kg)
Cisco Nexus 7706 Chassis (N77-C7706)
1 or 2
8.5 lb (3.9 kg)
Supervisor module (N77-SUP2E)
1 or 2
7.7 lb (3.5 kg)
Supervisor module (N77-SUP3E)
Cisco Nexus 7706 Hardware Installation Guide
OL-31330-01
118
Switch Specifications
Weights and Quantities for the Chassis, Modules, Fan Trays, and Power Supplies