Power Supply LEDs
Depending on the power supply (AC, DC and HVAC/HVDC power supplies), there are 1 or 2 input LEDs.
The Output, Fault, and ID LEDs have the same function for the AC, DC and HVAC/HVDC power supply
units.
Status
Color
LED
The AC, HVAC/HVDC, or DC input voltage is within the valid range.
Green
Input 1
The AC, HVAC/HVDC, or DC input voltage is outside the valid range.
Off
The DC input voltage is within the valid range.
Green
Input 2
(available
only on DC
power
supply
units)
The DC input voltage is outside the valid range.
Off
The AC or DC output power is within the valid range.
Green
Output
The AC or DC output power is outside the valid range.
Off
The AC or DC output voltage and power supply unit tests are okay.
Off
Fault
Self-diagnostic tests have failed or another power supply failure has occurred.
Flasing red
The operator has activated this LED to identify this module in the chassis.
Flashing blue
ID
This module is not being identified.
off
Cisco Nexus 7706 Hardware Installation Guide
165
OL-31330-01
LEDs