45.88(0x75) to 54.12(0x8a)
2017 Apr 3 16:54:50 SWITCH %PLATFORM-2-PFM_MODULE_POWER_OFF: Manual power-off of Xbar 5
from Command Line Interface
2017 Apr 3 16:54:50 SWITCH %PLATFORM-5-XBAR_PWRDN: Xbar 5 powered down (Serial number
JAE1921079X)
2017 Apr 3 16:54:50 SWITCH %PLATFORM-5-MOD_STATUS: Fabric-Module 5 current-status is
MOD_STATUS_CONFIGPOWERED_DOWN
2017 Apr 3 16:54:50 SWITCH %PLATFORM-5-MOD_STATUS: Fabric-Module 5 current-status is
MOD_STATUS_POWERED_DOWN
2017 Apr 3 16:58:40 SWITCH %PLATFORM-6-PFM_INFO: Fan Zone 1 : Fan Speed will change from
54.12(0x8a) to 45.88(0x75)
2017 Apr 3 17:00:41 SWITCH %PLATFORM-2-PFM_MODULE_POWER_ON: Manual power-on of Xbar 5 from
Command Line Interface
2017 Apr 3 17:00:41 SWITCH %PLATFORM-2-XBAR_DETECT: Xbar 5 detected (Serial number
JAE1921079X)
2017 Apr 3 17:00:41 SWITCH %PLATFORM-5-XBAR_PWRUP: Xbar 5 powered up (Serial number
JAE1921079X)
2017 Apr 3 17:00:41 SWITCH %PLATFORM-5-MOD_STATUS: Fabric-Module 5 current-status is
MOD_STATUS_POWERED_UP
2017 Apr 3 17:00:59 SWITCH %CARDCLIENT-2-SSE: XBAR:5 FABRIC ONLINE
The following example shows the syslogs displaying the fan tray maintenance mode being cancelled after the
post-cool period of 4 minutes is completed:
2017 Apr 3 16:20:08 SWITCH %PLATFORM-2-PFM_CRITICAL: FAN_MAINTENANCE_MODE: system is ready
for fan-removal.
2017 Apr 3 16:21:07 SWITCH %PLATFORM-2-FAN_REMOVED: Fan module 1(Serial number NCV2108V017)
Fan1(sys_fan1) removed
2017 Apr 3 16:21:08 SWITCH %PLATFORM-6-PFM_INFO: Fan Zone 1 : Fan Speed will change from
85.10(0xd9) to 74.90(0xbf)
2017 Apr 3 16:21:11 SWITCH %PLATFORM-1-PFM_ALERT: System shutdown in 3 days 0 hours 0 mins
0 seconds due to fan policy __pfm_
fanabsent_any_singlefan for fan1
2017 Apr 3 16:23:09 SWITCH %PLATFORM-6-PFM_INFO: Fan Zone 1 : Fan Speed will change from
74.90(0xbf) to 85.10(0xd9)
2017 Apr 3 16:25:09 SWITCH %PLATFORM-6-PFM_INFO: Fan Zone 1 : Fan Speed will change from
85.10(0xd9) to 100.00(0xff)
2017 Apr 3 16:25:33 SWITCH %PLATFORM-5-FAN_DETECT: Fan module 1(Serial number NCV2108V017)
Fan1(sys_fan1) detected
2017 Apr 3 16:25:33 SWITCH %PLATFORM-5-FAN_STATUS: Fan module 1(Serial number NCV2108V017)
Fan1(sys_fan1) current-status is F
AN_OK
2017 Apr 3 16:25:33 SWITCH %PLATFORM-2-FANMOD_FAN_OK: Fan module 1(Fan1(sys_fan1) fan) ok
2017 Apr 3 16:25:33 SWITCH %PLATFORM-6-PFM_INFO: Fan Zone 1 : Fan Speed will change from
100.00(0xff) to 45.88(0x75)
2017 Apr 3 16:25:33 SWITCH %PLATFORM-2-PFM_CRITICAL: FAN_MAINTENANCE_MODE_CANCELLED:
Reason(s): Temperature alarm: No, Superv
isor hot-inlet: No, Absent fans count: 0, Precool period completed: N/A, Postcool period
completed: Yes, Total maint. duratio
n: 564 seconds
If you need to remove the fan tray to replace a fabric module, see
Installing or Replacing a Fabric Module,
The fan tray displays the fabric module LEDs so that you can see the status of the two fabric modules installed
behind that fan tray.
Note
Cisco Nexus 7706 Hardware Installation Guide
93
OL-31330-01
Installing or Replacing Modules, Fan Trays, and Power Supplies
Replacing a Fan Tray