• If the wrist strap has a banana plug on the other end, insert the plug into the ESD port on the chassis (see the following
figure for the location of the port on the front of the chassis).
Figure 22: Location of the ESD Port on the Front of the Chassis
ESD port on the front of the chassis
1
• If the wrist strap has an alligator clip on the other end, clip that onto one of the two screws holding the grounding
lug to the chassis.
What to do next
After you ground yourself, you can replace the modules on the chassis.
Installing or Replacing a Supervisor Module
You can install or replace a supervisor module during switch operations so long as there is another supervisor
module installed and operating on the switch. If you eject the active supervisor from its slot in a chassis with
two supervisor modules, operations automatically switch over to the standby supervisor module. If you need
to replace a supervisor in a chassis with just one supervisor, you can install the new supervisor in the open
supervisor slot, make the new supervisor active, and remove the other supervisor module.
Cisco Nexus 7706 Hardware Installation Guide
OL-31330-01
82
Installing or Replacing Modules, Fan Trays, and Power Supplies
Installing or Replacing a Supervisor Module