Verify that there is power to the card by looking at the indicators on the power tray.
To verify which card needs attention, the Attention LED can be lit using the hw-module attention-led
location CLI command.
Note
If the installed or replaced FC fails to operate or power on after installation:
•
Ensure that the card is seated firmly in the Cisco NCS 4009 chassis slot. One easy way to verify physical
installation is to see whether the front faceplate of the FC is even with the fronts of the other cards
installed in the card cage.
•
Ensure that the ejector lever is latched and that the captive screws are fastened properly. If you are
uncertain, unlatch the levers, loosen the screws, and attempt to reseat the FC.
•
Examine the power system to see whether the chassis is receiving power.
About Line Cards
The Cisco NCS 4009 chassis supports both Optical Transport Network (OTN) line cards (LCs) and Dense
Wavelength-Division Multiplexing (DWDM) line cards. You can have a mix of both OTN and DWDM line
cards in the same chassis.
This section describes the following line cards:
For a list of the pluggable optics that are supported, see the
Pluggable Optics Support, on page 222
.
NCS4K-4H-OPW-QC2 Line Card
The NCS4K-4H-OPW-QC2 line card supports OTN, packet and WDM switching for 400G traffic and contains:
•
Two CFP2 ports. Each port can support 100 Gbps (DWDM QPSK) or 200Gbps (DWDM 16 QAM)
WDM signals
•
Four QSFP28/QSFP+ ports
The QSFP28 ports also support QSFP+ optics and can be used as 1x40G ports or 4x10G
ports.
Note
•
Six QSFP+ ports
The QSFP+ ports can be split and used as 1x40G ports or 4x10G ports.
Note
The NCS4K-4H-OPW-QC2 line card supports the following port configurations:
•
2-ports of 200 Gbps with CFP2 optics
Hardware Installation Guide for Cisco NCS 4000 Series
208
Installing Route Processor Cards, Fabric Cards, and Line Cards
About Line Cards