Replacing
LINF
Card
Step 17
Plug
the
HyperSwitch
100
power
cable
and
the console
terminal
power
cable
into
the
power
outlet
Setting
Communications
Software
Parameters
To
set
the
HyperSwitch
A100
and
console
terminal
communications
parameters perform
the
following
procedure
Step
Turn
ON
the console
terminal
power switch
Step
Set the
communications
parameters
on
the
console
terminal
as
follows
Line
transmission
rate
9600
bps
Data
bits
Parity
none
Stop
bit
bit
Flow
control
ON
Setting
System
Configuration
Data
To
set
the configuration
data perform
the procedures
in the section
Setting System
Configuration
Data
Replacing
LINF Card
This
section
provides
the
LINF
card
replacement
procedure
Required
Equipment
to
Replace
LINF
Card
Have
the following
equipment
available
when
replacing
the
LINF
card
New
LINF
card
or replacement
card
if removing
card
from one
slot
to
another
slot
Optical
cable
suited
to
the
LINF
card
Antistatic
bag
required
if
storing the replaced
LINF
card
Electrostatic
protection
kit
Standard
screwdriver
Phillips
screwdriver
Note
This
procedure
assumes
that
the console
terminal
and
the
HyperSwitch
A100
are properly
installed
Replacing
LINF
Card Procedure
Perform
the following
procedure
to
replace
the
LINF
card
Step
Provide
protection
against
static
electricity
Step
Turn
OFF
the
console
terminal
power
switch
Maintaining
and
Upgrading
the
HyperSwitch
A100
3-11