2-75
Catalyst 6500 Series Ethernet Modules Installation Guide
OL-6265-03
Chapter 2 Ethernet Switching Modules
1-Gigabit Ethernet Modules
Queues per port
•
With CFC daughter card:
–
Tx—1p3q8t
–
Rx—1q8t
•
With DFC daughter card:
–
Tx—1p3q8t
–
Rx—2q8t
Chassis/slot restrictions
The module is not supported in the Catalyst 6503 chassis.
Fabric connection
Single fabric channel.
Fabric channel speed
20Gb/sec
Module upgrades available
PoE support
Not supported.
Distributed forwarding
support
Ships with the WS-F6700-CFC daughter card factory-installed. The
module can be upgraded in the field to support dCEF with the
installation of a dCEF daughter card (WS-F6700-DFC3A,
WS-F6700-DFC3B, WS-F6700-DFC3BXL, WS-F6700-DFC3C, or the
WS-F6700-DFC3CXL).
Note
Refer to the
Catalyst 6500 Series CFC, DFC3A, DFC3B, and
DFC3BXL Installation Note
for additional information and
field upgrade procedures.
Pluggable transceivers
support
SFP transceivers are supported. Refer to your software release notes to
determine which SFP transceivers are supported. See the
“1-GB
Transceivers” section on page B-3
in Appendix B for additional
information on the SFP transceivers.
Digital Optical Monitoring
(DOM) supported
Not supported.
Module front panel LEDs
STATUS
•
Green—All diagnostics pass; the module is operational.
•
Orange—The module is booting or running diagnostics; an
overtemperature condition has occurred.
LINK
•
Green—The port is active (the link is connected and operational).
•
Flashing orange—The port failed diagnostics and is disabled.
•
Orange—The port is disabled.
•
Red—The module is resetting; an overtemperature condition has
occurred.
Note
If the module fails to download code and configuration
information successfully during the initial reset, the LED stays
red; the module does not come online.
•
Off—The port is not active or the link is not connected.
Table 2-46
WS-X6724-SFP Ethernet Module Features (continued)
Feature
Description