2-68
Catalyst 6500 Series Ethernet Modules Installation Guide
OL-6265-03
Chapter 2 Ethernet Switching Modules
1-Gigabit Ethernet Modules
Digital Optical Monitoring
(DOM) support
Supported on some GBIC transceivers
Note
Refer to your software release notes for specific information on
which GBIC transceivers support DOM and the software
release required for support.
Module front panel LEDs
STATUS
•
Green—All diagnostics pass; the module is operational.
•
Orange—The module is booting or running diagnostics; an
overtemperature condition has occurred.
LINK
•
Green—The port is active (the link is connected and operational).
•
Flashing orange—The port failed diagnostics and is disabled.
•
Orange—The port is disabled.
•
Red—The module is resetting; an overtemperature condition has
occurred.
Note
If the module fails to download code and configuration
information successfully during the initial reset, the LED stays
red; the module does not come online.
•
Off—The port is not active or the link is not connected.
Table 2-43
WS-X6416-GBIC Ethernet Module Physical and Environmental Specifications
Item
Specification
Dimensions (H x W x D)
1.2 x 14.4 x 16 in. (3.0 x 35.6 x 40.6 cm). Occupies one slot in the chassis.
Weight
7.0 lb (3.17 kg)
Power and heat numbers
•
Module current—2.81 A
•
Module power—118.02 W
•
AC-input power—147.53 W
•
AC heat dissipation—503.80 BTU/hour
•
DC-input power—158.63 W
•
DC heat dissipation—541.72 BTU/hour
Environment
Operating temperature
•
Certified for operation: 32° to 104°F (0° to 40°C)
•
Designed and tested for operation: 32° to 130°F (0° to 55°C)
Humidity (RH) ambient
(noncondensing)
10 to 90%
Operating altitude
•
Certified for operation: 0 to 6500 ft (0 to 2000 m)
•
Designed and tested for operation: –200 to 10,000 ft (–60 to 3000 m)
Table 2-42
WS-X6416-GBIC Features (continued)
Feature