Cisco Redundant Power System Hardware Installation Guide
Reading Error Messages on Cisco 2600 and 3600 Series Routers
B-10
Console Message Issued Upon Correction of Error:
When an external device console screen displays the Cisco IOS software
prompt (routername > or routername #)
“Redundant Power Supply
THERMAL condition is now normal”
When an external device console screen displays the ROMMON prompt
(rommon #>) no console message is issued when the error is corrected.
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated. The varbinds
included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState. The value of ciscoEnvMonSupplyState will be
normal.
Console Error Message:
When an external device console screen displays the Cisco IOS software
prompt (routername > or routername #)
“System detected
Redundant Power Supply THERMAL FAIL condition.”
The Cisco IOS software checks the condition once every 30 seconds. If
the condition still exists, the error message redisplays.
When an external device console screen displays the ROMMON prompt
(rommon #>)
“*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY THERMAL BIT IS
ASSERTED.”
TEMP LED is amber.
Description of Error:
The temperature inside the Cisco RPS is too hot.
SNMP Trap Issued Upon Error:
ciscoEnvMonRedundantSupplyNotification is generated. The varbinds
included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState. The value of ciscoEnvMonSupplyState will be
a warning.
Table B-2
Error Descriptions and LED Status (Continued)
RPS LED Status
Condition
Error Indicators, Descriptions, and Solutions
rpsappb Page 10 Monday, September 14, 1998 8:19 AM