Troubleshooting the Cisco RPS B-7
Reading Error Messages on Cisco 2600 and 3600 Series Routers
Console Message Issued Upon Correction of Error:
When an external device console monitor screen displays the Cisco IOS
software prompt (routername > or routername #)
“Redundant Power
Supply DC condition is now normal.”
When an external device console monitor screen displays the Cisco IOS
software prompt (routername > or routername #)
“Redundant Power
Supply DC condition is now normal.”
When an external device console monitor screen displays the ROMMON
prompt (rommon #>) no console message is issued when the error is
corrected.
SNMP Trap Issued Upon Correction of Error:
ciscoEnvMonRedundantSupplyNotification is generated. The varbinds
included are ciscoEnvMonSupplyStatusDescr and
ciscoEnvMonSupplyState. The value of ciscoEnvMonSupplyState will be
normal.
AC 1 or 2 LED is amber
or off.
FAIL
Console Error Message:
When an external device console monitor screen displays the Cisco IOS
software prompt (routername > or routername #)
“System detected
Redundant Power Supply AC FAIL condition.”
The Cisco IOS software checks the condition every 30 seconds. If the
condition still exists, the error message redisplays.
When an external device console monitor screen displays the ROMMON
prompt (rommon #>)
“*** System Environmental Interrupt ***
WARNING: REDUNDANT POWER SUPPLY AC FAIL BIT IS
ASSERTED.”
Table B-2
Error Descriptions and LED Status (Continued)
RPS LED Status
Condition
Error Indicators, Descriptions, and Solutions
rpsappb Page 7 Monday, September 14, 1998 8:19 AM