P/N 11934-003
8-27
Cirrus Design
Section 8
SR20
Handling, Servicing, Maintenance
Engine Compartment
Before cleaning the engine compartment, place a strip of tape on the
magneto vents to prevent any solvent from entering these units.
1.
Place a large pan under the engine to catch waste.
2.
Remove induction air filter and seal off induction system inlet.
3.
With the engine cowling removed, spray or brush the engine with
solvent or a mixture of solvent and degreaser. In order to remove
especially heavy dirt and grease deposits, it may be necessary to
brush areas that were sprayed.
• Caution •
Do not spray solvent into the alternator, vacuum pump,
starter, or induction air intakes.
4.
Allow the solvent to remain on the engine from 5 to 10 minutes.
Then rinse engine clean with additional solvent and allow it to dry.
• Caution •
Do not operate the engine until excess solvent has
evaporated or otherwise been removed
5.
Remove the protective tape from the magnetos.
6.
Open induction system air inlet and install filter.
7.
Lubricate the controls, bearing surfaces, etc., in accordance with
the Lubrication Chart.