2.1.1 Basic operations 

 

 

The basic operations include selecting the MU-2-R to use, setting the interface, selecting the mode and function 
window and so on.

 

 

 

The MU-2-R has 3 operation modes (command, text, and binary).

 

The transmission test function and air monitor function operate in the command mode. The buttons for these 
functions are disabled in modes other than the command mode.

 

 

Immediately after opening the COM port and when returning from the air monitoring function to the control and 
test window, the program automatically reads and resets the channel and Equipment ID, and these items are 
displayed on the control and test window screen. If you perform an unexpected operation, the Equipment ID 
may change to ‘FFh’, therefore always check the Equipment ID.

 

 

 

(1)  Always close the COM port before connecting the MU-2-R, changing the equipment, turning the power on and 

off and so on. If not, not only will the program shut down due to a COM port error, there may be adverse effects 
to the operation of the OS.

 

(2)  In the binary mode, characters entered in the input line of the control and test window are sent to the MU-2-R as 

they are input.

 

(3)  In order to return from the text mode to the command mode, the program sends the 1-byte ESC code:1Bh. 
(4)  An RS232C signal DTR line is used for switching between the binary mode, text mode, and command mode. 
(5)  When carrying out the various tests, check the User ID, Group ID, Equipment ID, Destination ID, transmission 

channel and the routing information in the control and test window. In particular, note that when finishing on the 
air monitoring function screen, the Equipment ID may be ‘FFh’ unless the power of the MU-2-R is turned off.

 

 

2.1 Basic Operations

 

Note

Chapter 2 How to Use the Evaluation Software

 

Summary of Contents for MU-2-R

Page 1: ...dio modem MU 2 R MU2 Evaluation Software Program MU2 ESP Operation Guide Version 1 0 Mar 2009 CIRCUIT DESIGN INC 7557 1 Hotaka Azumino Nagano 399 8303 JAPAN Tel 81 0263 82 1024 Fax 81 0263 82 1016 E m...

Page 2: ...2 2 5 Set route information panel 11 2 2 6 Route setting panel 12 2 2 7 Key input form 12 2 2 8 Transmission data auto assignment form 13 2 2 9 Binary code transmission form 14 2 2 10 Command issue p...

Page 3: ...ion Guide and the MU 2 R series product Operation Guides may be written as follows 1 When referring to products MU 2 R may be used to represent the MU 2 R series of products This should be understood...

Page 4: ...splaying them as a graph You can also display the field status of the target station using the relay function With the air monitor function the status of the radio waves changing from moment to moment...

Page 5: ...the Equipment ID 1 Always close the COM port before connecting the MU 2 R changing the equipment turning the power on and off and so on If not not only will the program shut down due to a COM port err...

Page 6: ...ta is opened in the air monitor window the colour of the button changes to flashing red when the data is displayed Clicking the button enables measurement with the equipment that is actually connected...

Page 7: ...ode 21 Command mode button Sets the MU 2 R to the command mode Normally you should use this mode 22 Binary mode button Sets the MU 2 R to the binary mode 23 Time counter A time measurement counter Thi...

Page 8: ...e the size of data sent at one time less than 255 bytes Screen The screen displays the commands and data sent from the data input lines and displays the command response and receive response returned...

Page 9: ...D is used In other words there are three methods sending in accordance with the content of the Destination ID or the content of the route register and directly entering the information in the command...

Page 10: ...line 1 The SHIFT F8 function key has the same function 4 Transmit 1 button Transmits the content of the data input line 1 to the MU 2 R The F8 function key has the same function If commands and so on...

Page 11: ...tem and clicking the Assign button 5 attaches the route information set with the route setting panel to the transmit command 5 Transmission data assignment button Clicking this button opens the transm...

Page 12: ...he equipment numbers of the relay stations The equipment numbers are shown in hexadecimal Clicking them opens a key input form for entering the equipment number When specifying multiple relay stations...

Page 13: ...OK button Confirms the character string for data transmission The created data is displayed in the data input line 1 4 Data size Specifies the data size The range that can be specified is 0 to 255 byt...

Page 14: ...tive cell of the transmit data cells 12 with a left mouse click To store characters in these cells press a right mouse button on the cell and enter a character from the keyboard 4 ASCII code list 5 Tr...

Page 15: ...nication link related commands and check the internal states Pressing the Get link parameter button acquires multiple parameters Pressing the Link parameter Ini button initializes the link parameters...

Page 16: ...nt value of packets being sent 6 Number of packets setting 3 Sets the number of packets to send To improve the accuracy of success rate measurement it is necessary to set 100 or more 7 Start stop butt...

Page 17: ...ecify the route information on the route setting panel If the route information is not set the setting of the Destination ID will be acquired 1 Display area for internal setting values Acquires and sh...

Page 18: ...annel to change 3 Fix in EEPROM Check this to fix the changed channel in the EEPROM 4 Route test button Tests whether the current system is linked normally before changing the channels 5 Result Shows...

Page 19: ...station for only the time specified 16 Start stop button 17 Set data button 18 Packet transmission interval 19 Number of packets 20 Transmission of packets with serial numbers You can assign a serial...

Page 20: ...the target station 4 Data setting button The character string shown in the data input line is shown on the transmitting display in the colour of the button 5 Transmit F9 button The character string sh...

Page 21: ...ge Indicates the data size of the file for transmission in bytes 3 Transmit screen mode switcher Switches the display mode of the transmitting box between Hex and Text In the text mode text files are...

Page 22: ...nal receive buffer of the program 13 Receive indicator Shown in green when data is being received 14 Received JPEG image Displays the received JPEG image 15 Data size of the received file JPEG image I...

Page 23: ...option W command you can make the MU 2 R emit test waves continuously as long as the power is turned on Peak hold The peak is the RSSI level of each channel during the period of measurement and you ca...

Page 24: ...a frequency domain and AMT for a time domain 6 Date and time line Sets the date and current time shown in the graph The current time is updated with a left mouse click It is cleared with a double cli...

Page 25: ...channels Always set the end channel higher than the start channel 18 Progress bar Displays the progress of data acquisition for each channel 19 Route setting panel Sets the routing information to the...

Page 26: ...Measurement stops when the number of samples set with the sampling number control is reached The measurement time interval is set with the sample time control 7 Enable area line function Selects wheth...

Page 27: ...e hidden with the F7 function key 2 4 3 Air monitor mouse functions 1 Analyse function When measurement is stopped you can click on the graph of each channel and display the RSSI absolute level and fr...

Page 28: ...normally 2D F4 13 Load graph data Ctrl L Loads saved graph data Do NOT load files with a file extension other than AMF or AMT 14 Save graph data Ctrl S Saves graph data as a file Do not change the fi...

Page 29: ...e initialization file 3 Cancel button 4 Edit enable checkbox The MU 2 R normally operates with just the port and baud rate specified but you can change the other parameters for testing and the like 5...

Page 30: ...pop up menu is displayed with a right mouse click 2 Quit button Quits the image viewer 3 Load image button Displays the load image file dialogue 4 Copy to the clipboard button Copies images to the cl...

Page 31: ...the colour of the main bar when it exceeds the threshold Peak bar Normal Changes the colour of the peak value bar Threshold line Changes the colour of the threshold line Main bar Analyse line Changes...

Page 32: ...ircuit Design MU2_ESP folder When uninstalling the program first move important files to another location AMF Air monitor data frequency domain AMT Air monitor data time domain test jpg Temporary imag...

Page 33: ...cuits and reverse connections may result in overheating and damage and must be avoided at all costs Ensure that the power supply has been switched off before attempting any wiring work The case is con...

Page 34: ...OG_MU2 ESP_v10e 34 Circuit Design Inc OPERATION GUIDE REVISION HISTORY Version Date Description Remark 1 0 Mar 2009 MU2 ESP The first issue...