OPERATION GUIDE
[12] Number of transmitted packets
Shows the number of packets transmitted
[13] Continuous command transmission panel
By pressing the ‘Start’ button, the command character string entered in the data input line 1 is continuously
transmitted for the time specified with the ‘Interval’.
[14] Issue target station test data
Pressing this button issues test data from the target station specified with the route information on the route
setting panel for only the time specified.
[15] Issue source station test data
Pressing this button issues test data from the source station for only the time specified.
[16] Start/stop button
[17] Set data button
[18] Packet transmission interval
[19] Number of packets
[20] Transmission of packets with serial numbers
You can assign a serial number to each of packets to send. The serial number is a hexadecimal integer. The
transmission time 't' with standard protocols can be calculated depending on the number of transmission
characters 'n' as follows;
t=2.08ms*n+100ms
Set the transmission data using the "Set data" button [13]. 8 characters are used for a serial number, therefore
ensure that the number of transmission characters is less than 247.
[21] Time for issuing test data
Specifies the time for issuing test data in 10-second units.
[22] Test data transmission panel
Transmits test data from the source station or target station for the time specified.