23
Material Tank Capacity
Material Tank Capacity
Material Tank Capacity
Material Tank Capacity
Material Depth
Model 1500
1570 Cubic Inches*
2"
13.6
4"
26.32
6"
39.48
8"
52.64
10"
65.80
12"
78.96
14"
92.12
16"
105.58
18"
118.44
20"
131.60
22"
144.76
PROBLEM
CAUSE
SOLUTION
Material recirculates but will
notflow through sealing wand.
Sealing hose froze up.
Remove wand and place hose
incabinet to melt material.
Sealing wand froze up.
Heat wand and melt material.
Sealing hose valve not completely
open.
Open valve to the full "on" position.
Wand trigger not engageing
Check wand switch to see if power
is going trhough.
Material heat up time slow.
Burner orifice clogged.
Remove orifice and clean.
Hot oil pump worn.
Replace or rebuild pump.
Heat transfer oil is worn out.
Check oil level. Replace if
necessary.
During sealing operation, material
stops flowing.
Wand valve left in "off" position
too long before returning to access
port for recirculation.
Place hose in cabinet to melt
material. Refer to heating a
plugged hose on page.
Too many biscuits added at one
time causing coldmaterial to enter
pump.
Heat hose and plumbing
system.Reverse pump momentarily
toforce cold material into tank.
Material temperature too low.
Check control box settings.
Trouble Shooting
Trouble Shooting
Trouble Shooting