![CIMLINE MATRIX 1500 Owner'S/Operator'S Manual Download Page 8](http://html.mh-extra.com/html/cimline/matrix-1500/matrix-1500_owners-operators-manual_2607228008.webp)
8
Starting the Engine
Starting the Engine
Starting the Engine
Starting the Engine
NOTE: Read the engine instruction manual before starting.
NOTE: Read the engine instruction manual before starting.
NOTE: Read the engine instruction manual before starting.
NOTE: Read the engine instruction manual before starting.
Engine RPM is factory set and fixed at 3000 RPM.
Engine RPM is factory set and fixed at 3000 RPM.
Engine RPM is factory set and fixed at 3000 RPM.
Engine RPM is factory set and fixed at 3000 RPM.
Diesel Engine:
Diesel Engine:
Diesel Engine:
Diesel Engine:
Your Isuzu Diesel Powered Melter is equipped with an electronic shut-
down system . If the system detects excessive water temperature, low
alternator output, or low oil pressure, the engine will automatically shut
down. The indicator light that remains on indicates the malfunction. An
integral digital hour meter records engine run time,
The engine must be running before igniting the burner. The burner will
only operate if the ignition key is turned on.
DO NOT
turn on burner
without engine running.
Automatic Temperature Control Setting
Automatic Temperature Control Setting
Automatic Temperature Control Setting
Automatic Temperature Control Setting
NOTE: On diesel units, the engine must be running before activating temperature
NOTE: On diesel units, the engine must be running before activating temperature
NOTE: On diesel units, the engine must be running before activating temperature
NOTE: On diesel units, the engine must be running before activating temperature
control. The automatic temperature control system monitors the heat trans-
control. The automatic temperature control system monitors the heat trans-
control. The automatic temperature control system monitors the heat trans-
control. The automatic temperature control system monitors the heat trans-
fer oil temperature and material temperature.
fer oil temperature and material temperature.
fer oil temperature and material temperature.
fer oil temperature and material temperature.
1)
Set the oil controller (A) to 550º F(288º C) (See Setting Temperature Control-
lers, pg. 10)
2)
Set the material controller (B) to the recommended material working tempera-
ture which is typically listed on the material container.
3)
Turn switch (H) on to activate the heated hose.
(Continued on page 9)