![CIMLINE MATRIX 1500 Owner'S/Operator'S Manual Download Page 12](http://html.mh-extra.com/html/cimline/matrix-1500/matrix-1500_owners-operators-manual_2607228012.webp)
12
Material System Cleanout
Material System Cleanout
Material System Cleanout
Material System Cleanout
NOTE: The material loading doors and wand access port must be closed at all
times.
REVERSE FLOW CLEANOUT METHOD (Diagram 13)
1)
To clean out the machine at the end of the day, return the wand to the access
port (B) and pin trigger. Go to the Run the pump in reverse for 2 - 3 minutes.
2)
Go to the control box and flip the pump toggle switch to the reverse mode (see
page 9). Run the pump in reverse for 2 - 3 minutes.
3)
Turn off engine (see page 8).
4)
Return pump toggle to the forward operation.
5)
Unpin and remove wand from access port and place in wand holder.
FLUSHING NON-REHEATABLE MATERIALS
(must have optional draincock)
1)
Pump the material tank as low as possible and open draincock to empty tank.
2)
Add 5 to 10 gallons of recommended flushing solvent to tank through the ac-
cess port.
3)
Place the wand into access port and open wand valve.
4)
Circulate the solvent approximately 5 to 10 minutes.
5)
Pump the solvent through the wand into a container and dispose of it accord-
ing to EPA
guidelines.
6)
Add another 5 to 10 gallons of material and circulate for 5 minutes.
7)
Pump this 5 to 10 gallons into empty containers and reuse it for the first purge
next time the unit is used.